Cadac CDC five_02-01-2020_Rev-7.docx
Page. 39 / 78
Optional Power Supply
If an optional external CDC PSU 4800 power supply is being used it should be connected using the
supplied cable to the 12-pin Jaeger connector fitted to the rear of the surface. There are three DC
power rails: +17 V, -17 V and +12.5 V.
17: PSU4800 (front / rear)
Front Panel
1.
POWER:
The on/off switch for the supply
2.
Mains Fuses
. One each in the line and neutral of the AC input. See table below for ratings
3.
DC output LEDs
: One red LED for each DC output
4.
Air intakes
: Do not obstruct
Rear Panel
5.
Mains Input:
Neutrik
®
powerCON
®
TRUE1 male connector for AC mains. Max rating 16 A. A
female powerCON
®
connector is also provided; this is paralleled to the input connector. It may
be used to link AC mains to a second PSU or other equipment. Total AC current consumption
when li
nking units in this way must not exceed the input connector’s current rating of 16 A.
6.
Power Output:
Locking 12-pin Jaeger connector. Use the supplied cable to connect CDC five.
7.
Air exhaust vents
: Do not obstruct
The PSU is of the “Universal” type and will operate on all mains voltages from 90 to 250 V, 50/60 Hz.
The PSU is rated at 1200 W AC.
Fuse Data
Voltage
Rating
Type
230 V
3.15 A
20 mm T3.15AL 250V
115 V
6.3 A
20 mm T6AL 250V
1
2
3
4
7
5
6