Chapter 2: Local Management
2-10
WPIM-DI Local Management Guide
Max Xmit Unit
User-configured field that displays the maximum packet size that can be
transmitted on the selected interface. The default settings for this field are
8191 for PPP and 4095 for Frame Relay.
Line Coding
Displays the Line Coding for Timeslots associated with this interface.
This field displays JBZS, INV-HDLC, or None. The default setting for
this field is NONE.
Active Protocol
Displays the active OSI Layer protocol. This field displays
PPP (Point-to-Point), FR (Frame Relay), or NONE. The default setting is
NONE.
If PPP is selected, the following field appears:
PPP Type
:
This field displays BNCP or LEX. The default
setting is BNCP.
If FR is selected, the following field appears:
FR LMP
:
This field displays the Link Management
Protocol NO LMI, Q.933-A or T1.617-D. The
default setting is T1.617-D.
If NO LMI is selected for FR LMP, the following fields are displayed:
DLCI Address
:
This field can be set to values from 0-1023. The
values 0-15 and 1008-1022 are reserved Data
Link Connection Identifiers (DLCI) addresses.
The values 16-991 are typically used for virtual
circuits.
Circuit State
:
Steps between Active, Inactive and Invalid. The
default setting is Active.
PT#
Displays the application ports (bridge ports) available from the host
platform to the WAN. If the active protocol is PPP, Local Management
assigns only one application port per interface number (IF#). If the active
protocol is Frame Relay, Local Management assigns the available WAN
bridge ports from the host platform, one per DLCI.