15
5.4
Mounting the blow tube
1
2
3
Fig. 9
Mounting the blow tube
It is possible to rotate the blow tube to optimize the support with the support air for the take over procedure of the
label from printer to applicator.
1. Loosen screw (1).
2. Put in the blow tube (3) into the hole A (2).
3. Tighten screw (1) easily to secure it
„6.2 Blow Tube and Support Air Adjustments“
5.5
Connecting the Compressed Air
!
Attention!
Adjustments and function control was made with a compressed air value of 4.5 bar. The applicator
operating range is between 4.0 and 6.0 bar.
!
Warning!
When the applicator is connected to the compressed air cylinder movements are possible.
Do not reach into the zone of the moving pad and keep long hair, loose clothes, and jewelry distant.
2
1
3
4
1 Check that the stop valve (2) is closed shown
in figure 11.
2.
Attach compressed air at the fitting (1).
3. Open the stop valve (2) .
4. Switch on the printer by the power switch.
It is possible to use a air pressure regulation unit
Air pressure regulation unit with included
magnetic valve (3)
Controlling via printer
Interface description of the printer
Air pressure regulation unit (4)
Fig. 10
Compressed air connection
i
Note!
If the pad is not in the start position when the printer is switched on an error message appears on the
display.
Press button pause at the printer.
The applicator will move into the start position and is ready for work.
i
Note!
Mount and use the air pressure regulation unit only in the shown orientation. Otherwise the function of the air-water
separator can not be guaranteed.