iNetVu™ Service Manual
Page 29 of 109
3.2.1.5. Elevation Jam Error
Cause:
Indicates that current is being sent to the Mobile Platform to deploy the
elevation, but the Elevation angle does not change.
Solution 1:
Ensure that the Motor Control Cable is securely connected at the iNetVu™
controller and Mobile Platform.
Cause 2:
If the Mobile Platform physically moves, and the Stow ST Limit is off, but
the Elevation angle doesn’t change, then it may be a problem related to
the Inclinometer.
Solution 2:
Replace inclinometer (refer to section 4.4 of this manual)
Cause 3:
If the Mobile Platform doesn’t physically move and there is no Elevation
current reading, then it may be a problem related with the iNetVu™
Controller.
Solution
3:
Contact C-Com Satellite Systems Inc Support.
Cause 4: Burned Fuse.
Solution
4: Replace the 15 AMP Elevation Motor Fuse on the controller
board.