To decrease the DN Limit Angle (i.e. Switch turns on sooner), rotate the
magnetic bracket towards from the Limit Switch (counter-clockwise).
Stow (ST) Limit Switch
After clicking
Stow Antenna
, The Mobile Platform will lower itself until the Elevation ST
Indicator comes ON. At this time, the Mobile Platform will pause, then initiate a short 2
nd
drive downwards. This 2
nd
drive downwards should begin
BEFORE
the reflector makes
contact with the roll bar/soft pad.
Be prepared to click the STOP button should Mobile Platform’s 2
nd
drive does not
initiate prior to the Reflector making contact.
Adjust the Elevation ST Switch’s magnet block to ensure that the reflector firmly secured on the
roll bar/soft pad after the 2
nd
drive downwards.
1)
Remove Elevation Cover.
2)
Locate Elevation ST Limit Switch.
3)
Start iNetVu Mobile Software.
4)
Go to
Advanced Controls
.
5)
Click
Stow Antenna
.
6)
Adjust the space between the Limit Switch and Magnet to
3-5 mm
by loosening
the Locking Nuts and sliding the Limit Switch either closer to or further from the
Limit Switch, and also adjusting the position of the Magnet Block to help
accommodate the
3-5 mm
gap.
7)
If the Antenna does not make contact with the roll bar/soft pad after the 2
nd
drive,
or if the Antenna appears to “over-stow”, raise the Elevation and re-adjust the
magnet block, by loosening the locking screws until satisfactory results are met.
It is imperative to maintain the 3-5 mm gap between the Limit Switch and Magnet
at the Elevation at which the Elevation ST Indicator comes ON.
To increase the ST Limit Angle (i.e. Switch turns on earlier), move the
magnetic bracket upwards.
To decrease the ST Limit Angle (i.e. Switch turns on later), move the
magnetic bracket downwards.
If the above procedure did not solve your problem then contact iNetVu support for further
assistance.