MAINTENANCE
OPERATOR MANUAL
40
EPS14P
41
OM-EPS14P2019001-EN
4. Electric System
(1) Check connectors and tighten the loose parts. Check electrical connectors for abnormality
(for example, sign of burning).
(2) Check fuses of main controller and replace them if necessary. Check whether the copper
busbar of the main controller is burnt. If so, replace it.
(3) Check if fuse and relay work properly and replace them if necessary.
Warning
Disconnect the battery before checking the electric system.
5. Others
Check torque on critical fasteners.
CONSUMABLE ITEMS
Type and Parameters of Consumable Items
Item
Consumable Items
Volume Needed
Type
Gear Oil Level Checking
Gear Oil
1.05 L
SAE 80W-90
Chains Lubrication
Machine Oil
As Needed
20#(Winter), 40#(Other Seasons)
Hydraulic Oil Replacement
Hydraulic Oil
9 L
ISO VG46, ISO VG68
Note
The given quantities are maximum values and take the actual quantities as the standard.