22
EN
Installation check 1/4: Waste water connection
according to EN1717
►
Check that the waste water hoses are connected
properly (see chapter
18).
If all criteria for correct installation are satisfied:
►
Press
INSTALLED
.
Installation check 2/4: Ports on the connection
fitting
►Ensure that the hoses for the inflow and outlet
water at the connection fitting are correctly con
-
nected (see chapter
►
Open the connection fitting by turning the
handwheel anti-clockwise until it stops. Rinsing
of the product starts.
If all criteria for correct installation are satisfied:
►
Press
INSTALLED
.
Installation check 3/4: AQA Stop Sensor
►Check the connection and position of the floor
sensor (see chapter
If all criteria for correct installation are satisfied:
►
Press
CONFIRM
.
Installation check 4/4: Refilling the regenerative
►
Press lightly on the Easy Fill technology cover to
open it (see chapter
19).
►
Add up to 30 kg of regenerative (regenerative
tablets in accordance with DIN EN 973 type A) to
the regenerative container. The maximum level
of 100% on the display corresponds to a filling
level of approx. 46 cm.
Caution:
Do not fill with water!
►
Press the Easy Fill technology cover down gently
until it snaps shut.