PROTECTION & SAFETY
19
2020/06 - Indice de révision : A - Code : 34560
3.1.
Slaving
Slaving is possible via a potential free dry contact (refer to the diagram on the previous page and the wiring
diagram).
Slaving can be associated with the filtration pump, booster pump, etc.
The connection at the relay in the automatic cover electrical panel is normally open (NO). This must be changed
to normally closed (NC) to carry out slaving.
Filtration panel wiring diagram:
3.2.
Coverdeck AX-IN deck box
In the deck box, connect the 5 motor wires to the terminal block. The motor cable is comprised of:
‐
2 wires for the sensor signal (S),
‐
2 wires for the sensor power supply (A/C),
‐
2 wires for the motor power supply (rotation dir/-).
Connecting the cable in the deck box.
*The orange wire is not used
The deck box features two cable glands, one for the power supply cable and one
for the signal cable. Leaktightness of the signal wire is ensured by the cable gland
(9). The seal Ø30.5x5 (4) should be threaded onto the motor cable to retain the
two-component gel in the deck box.
Once correct operation of the cover has been verified
(direction of rotation of
the axle, memorisation of ends of travel, etc.), and the deck box has been fixed, it can be filled with the removable
waterproof gel (supplied) to protect the contacts against humidity.
If the rotation of the axle is incorrect, invert it as shown in the section describing the printed circuit board.
Sensor signals
Sensor power supply
Motor power supply
White
Brown (+24V DC)
Blue (0V DC)
Red
Black
Sensors