PROTECTION & SAFETY
39
2020/06 - Indice de révision : A - Code : 34560
Undo the screws (8) to mount the wall support on the bracket.
Sealing plate assembled in the factory
Ref
Description
Qty
1 Screw H M12x30 SS A4
2
2 Sealing plate*
1
3 UPAT M12x69 A4 bushing
2
4 Gasket 90x49
1
5 Adjustable left-hand linkage
1
6 Nut H M12 brass
6
7 Washer M12 SS A4
6
8 Screw H M12x30 SS A4
2
9 Bearing M12x15 PA6
2
10 Adjustable right-hand linkage
1
*In the case of coping 20 mm thick, use M20 sealing plates (available as an option, not supplied with the bracket).
Trace the location of the sealing plates according to the bracket installation diagram enclosed that corresponds
to your order.
Put the plates in position, ensure that they are level and at the same height.
Counter-drill through the holes in the top portion of the sealing plate using a Ø 16 mm concrete bit for
M30/M40/M55 plates and Ø 10 mm for M20 plates. Fix the plates in position and check that they level and at
the same height (use wedges if necessary).
Undo the screws (8) to mount the sealing plate on the bracket. Assemble the plate on the bracket according to
the height of the coping:
The locking nuts of the foot should be 8 mm from the foot. Tighten the linkages
moderately.