WF-WK100
WiFi Wireless
Cost-effective
Inclinometer
Bewis Sensing Technology LLC
www.bwsensing.com
Tel:
+86 189
2129 2620
1-10-1
Set zero mode
It can be configured as absolute zero (ABSOLUTE) or relative zero (RELATIVE). If configured as relative zero,
the current angle will be regarded as the zero point. The default is absolute zero.
Send: ZRELATIVE or ABSOLUTE
Or Z+R or A
Return: OK
1-10-2
View all sensor configuration and information
Send: STATUS
Or S
Return: All configuration and information and OK
1-
1-11
Display configuration SHELL
The following commands can configure the sensor's echo mode and power-on printing.
Need to send SAVE+ALL or SAVE+SHELL to save the configuration
1-
1-11-1
Configure echo mode
The echo mode can be configured as minimal (MINIMALIST), standard (NORMAL) or advanced
(ADVANCED), and the default is standard.
In advanced mode, in the serial port tool that supports Linux special characters, special information will
be marked with different colors, which can be viewed and operated more conveniently.