g Send SAVE+ALL to save the configuration.
2
Low-power operating mode configuration
If the frequency of collecting data is low (for example, the frequency is less than once per minute), configuring the
sensor to work with low power consumption can greatly increase the standby time of the sensor and reduce the
charging frequency. After the sensor has been able to send data to the receiving device via WLAN, perform the
following operations to configure the sensor to work in low power consumption.
Assuming that the WLAN and Socket information have been correctly configured, the data can be received
normally.
a Send any recognizable string command (such as HELP) to make the sensor exit silent mode. This step is not
necessary.
b Send WAKEU60, and set the sleep wake-up period to 60 seconds. Set to 0 or any value not
greater than the wake-up hold time to turn off the sleep function. For command details, refer to section 1-6-1 in
"String Command".