INSTRUCTION, USE AND
MAINTENANCE MANUAL
GB
Page 35 of 68
6. Proceed in the same way as described in points
1-2-3.
BEFORE REMOVING THE DIAME-
TER-DISTANCE CALIPER, PRESS
THE BRAKE PEDAL AND HOLD IT
DOWN UNTIL THE WEIGHT HAS
NOT BEEN APPLIED, ENSURING IN
THIS WAY THAT, DURING THESE
PHASES, THE WHEEL CAN NOT
ROTATE.
•
Weights fitting with laser (at "6 hours").
THE MACHINE (IF PRE-SET WITH
FIXED LASER, ON DELIVERY IT
IS SET WITH THE OPTION DESE-
LECTED).
TO USE THIS MODE, IT IS NECES-
SARY THAT THE RELEVANT FUNC-
TION IS ENABLED
ON THE
MENU "OPTIONS" DESCRIBED IN
PAR. 15.1.
TO USE THIS WEIGHT APPLICA-
TION MODE THE OPERATOR
MUST REMEMBER THE PRECISE
POINT WHERE THE MEASURE-
MENT WAS TAKEN WITH THE
DISTANCE-DIAMETER CALIPER
ARM.
At the end of the spin, on the rim at "6 hours" is
displayed a laser beam (blade) indicating the axis
on which to apply the weight. The positioning of the
weight (s) in depth shall be at the discretion of the
operator, depending on where remembers taking
the measure.
BE SURE TO APPLY THE WEIGHT
(INTERNAL OR EXTERNAL) AS
INDICATED BY THE 2 GREEN AR-
ROWS
(
Fig. 52 ref. 2 or 3
)
ON THE
CORRESPONDING
MONITOR SCREEN.
•
Weights fitting at “6 o'clock” (without the use of
lasers).
TO USE THIS MODE, IT IS NECES-
SARY THAT THE RELEVANT FUNC-
TION IS ENABLED
ON THE
MENU "OPTIONS" DESCRIBED IN
PAR. 15.1.
TO USE THIS WEIGHT APPLICA-
TION MODE THE OPERATOR
MUST REMEMBER THE PRECISE
POINT WHERE THE MEASURE-
MENT WAS TAKEN WITH THE
DISTANCE-DIAMETER CALIPER
ARM.
USING THIS MODE, THE MACHINE
ALLOWS YOU TO APPLY ANY AD-
HESIVE WEIGHTS THAT WOULD
BE APPLIED TO "12 HOURS" TO
"6 O'CLOCK". IF, AFTER YOU EN-
ABLE THIS MODE, ON BALANCING
PROGRAM APPEARED AGAIN THE
ICON (ONLY IN THIS CASE)
THE ADHESIVE WEIGHT WILL BE
APPLIED TO "12 HOURS".
At the end of the spin, the wheel stops in place to
apply the weight at "6 o'clock". The positioning of
the weight (s) in depth shall be at the discretion of
the operator, depending on where remembers taking
the measure.
BE SURE TO APPLY THE WEIGHT
(INTERNAL OR EXTERNAL) AS
INDICATED BY THE 2 GREEN
ARROWS
(
Fig. 52 ref. 2 or 3
)
ON
THE CORRESPONDING MONITOR
SCREEN.
•
Weights fitting at “12 o'clock” (with the use of
laser) (optional).
TO USE THIS MODE, IT IS NECES-
SARY THAT THE RELEVANT FUNC-
TION IS ENABLED
ON THE
MENU "OPTIONS" DESCRIBED IN
PAR. 15.1.
This function indicates, through the 2 laser pointers
placed on the machine (frame and wheel cover), the
centre line position (at 12 o’ clock) of the counter-
weight in the programs that require the clip weights
(ex: dynamic) for the wheel balancing.
Therefore, at the end of the measuring cycle, when the
wheel stops in position to fit the clip weight (green ar-
rows an the screen), the laser corresponding to the side
to balance turns on, projecting a line onto the rim edge.
1297-M008-4_B
LIBRAK355 - LIBRAK355P - LIBRAK355S - LIBRAK355PS - LIBRAK355WS - LIBRAK355PWS