INSTRUCTION, USE AND
MAINTENANCE MANUAL
1
2
3
Fig. 34
7. Fit the cone (
Fig. 35 ref. 3
) with the narrowest part
turned towards the wheel.
8. Fit the grip-ring (
Fig. 35 ref. 1
) in the bush (
Fig. 35
ref. 2
) and bring everything against the wheel.
3
1
2
Fig. 35
THE GRIP-RING (FIG. 35 REF. 1)
MUST BE MOUNTED WITH THE
DISCHARGE SIDE TOWARDS THE
SLEEVE (FIG. 35 REF. 2).
Close the pneumatic mandrel by lifting the appropriate
control pedal.
DURING MANDREL OPENING/
CLOSING OPERATIONS, BE CARE-
FUL TO KEEP YOUR HANDS AND
OTHER PARTS OF THE BODY
AWAY FROM THE MANDREL.
12.3 Adjustment of ultrasound sensor sup-
port (standard for LIBRAK355WS -
LIBRAK355PWS models) (optional for
LIBRAK355 - LIBRAK355P models)
Ultrasound sensor support (
Fig. 36-37 ref. 1
) must
be used in the “fully-lowered” position, as shown in
Fig. 36
.
However with wheels with great diameter, you can set
it higher so that the wheel can be mounted easily onto
the mandrel (see
Fig. 37
).
In order to carry out the adjustment, just loosen the
handwheel (
Fig. 37 ref. 2
) and place the support in
the wished position.
At the end tighten the handwheel (
Fig. 37 ref. 2
).
Fig. 36
Fig. 37
1297-M008-4_B