Chapter 2
BK730-2
Base
Page 2-14
2.2.4.1
Dip Switch Settings
The Speed Control Board has two 8 position DIP switches used to configure its operating
mode based on the system’s setup requirements and position in the Production line.
list the switch assignments for DIP S2
and
S3 respectively.
Table 2-3:
DIP switch setting definitions for DIP S2.
Switch Position(s)
Description
Position 1
On if Photo 1 is Normally Closed
Position 2
On if Photo 2 is Normally Closed
Position 5, 6
Feedback Encoder Resolution as follows
5:6 = Off:Off
660 DPI
5:6 = On:Off
600 DPI
5:6 = Off:On
Not Used
5:6 = On:On
Not Used
Position 7, 8
Follower Encoder Resolution as follows
7:8 = Off:Off
660 DPI (Or for last Transport)
7:8 = On:Off
600 DPI
7:8 = Off:On
Not Used
7:8 = On:On
Not Used
Table 2-4:
DIP switch setting definitions for DIP S3.
Switch Position(s)
Description
Position 1
On to calibrate for 0 m/s
Position 2
On to calibrate for 1 m/s
Position 3
On to calibrate for 17 inch pitch
Position 4
On for “Follower” operating mode
Position 5
On for “Gap Control” operating mode
Position 6
Not Used
Position 7
Not Used
Position 8
On for “Master Follower” operating mode
Note:
Only 1 switch can be enabled at any given time for DIP S3.
Buskro Ltd.
BK730-2 Tabber
Summary of Contents for BK730-2
Page 1: ...BK730 2 Tabber 2 Part No 9104528 User s Guide V1 2 ...
Page 5: ...General Information Buskro Ltd BK730 2 Tabber Chapter 1 1 0 General Information ...
Page 14: ...BK730 2 Base Buskro Ltd BK730 2 Tabber Chapter 2 2 0 BK730 2 Base ...
Page 41: ...Mechanical Adjustments Buskro Ltd BK730 2 Tabber Chapter 3 3 0 Tabber Labeler Head BK731 2 ...
Page 58: ...User Interface Buskro Ltd BK730 2 Tabber Chapter 4 4 0 User Interface ...