Product Description | 2
Instruction Manual MINK MM 1104-1142 BV_EN_en
7 | 36
2.3.2
Aqua Version
The Aqua version is a design option for conveying condensable vapors (water).
This machine is specifically equipped with:
– corrosion protection coating
– optional condensate drain (CD) in the internal silencer.
2.4
Start Controls
The machine comes without start controls. The control of the machine is to be provided in the
course of installation.
The machine can be equipped with a soft-starter.
2.5
Optional Accessories
2.5.1
Inlet Filter
The inlet filter protects the machine against dust and other solids in the process gas. The inlet filter
is available with a paper or polyester cartridge.
2.5.2
Vacuum Relief Valve
The ultimate pressure is limited by a vacuum relief valve (VRE). The vacuum relief valve is adjusted
ex-works to the minimum permitted ultimate pressure (see nameplate).
2.5.3
Condensate Drain
The condensate drain (CD) uses to drain the accumulated fluids.