5 | Installation
10 | 36
Instruction Manual MINK MM 1104-1142 BV_EN_en
5
Installation
5.1
Installation Conditions
WARNING
Gas tight version:
The machine is not absolutely gas tight, possible leakages of dangerous media.
Risk of poisoning!
Risk of infection!
●
Make sure that the ambient atmosphere of the machine is sufficiently ventilated.
Closed air cooling systems are not suitable and therefore prohibited.
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
●
Take care that the installation conditions are fully complied with.
~1 m
~1 m
~1 m
~1 m
●
Make sure that the environment of the machine is not potentially explosive.
●
Make sure that the ambient conditions comply with the
●
Make sure that the environmental conditions comply with the protection class of the motor and
the electrical elements.
●
Make sure that the installation space or location is protected from weather and lightning.
●
Make sure that the installation space or location is vented such that sufficient cooling of the ma-
chine is provided.