background image

UK Declaration of Conformity

This Declaration of Conformity and the UKCA-mark affixed to the nameplate are valid for the machine within the

 

Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer.

 

When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery

 

(this can be the operating company, too) must conduct the conformity assessment process for the superordinate

 

machine or plant, issue the Declaration of Conformity for it and affix the UKCA-mark.
The manufacturer

declares that the machine(s)

COBRA

 BC 0101 G

 

fulfil(s) all the relevant provisions from UK legislations:

– Supply of Machinery (Safety) Regulations 2008

– Electromagnetic Compatibility Regulations 2016

– Restriction of the use of certain hazardous substances in electrical and electronic equipment Regulations 2012

and comply(-ies) with the following designated standards that have been used to fulfil those provisions:

Standard

Title of the Standard

BS EN ISO 12100 : 2010

Safety of machinery. Basic concepts, general principles of design. Risk assess-
ment and risk reduction.

BS EN ISO 13857 : 2019

Safety of machinery - Safety distances to prevent hazard zones being reached
by the upper and lower limbs.

BS EN 1012-1 : 2010
BS EN 1012-2 : 1996 + A1 : 2009

Compressors and vacuum pumps. Safety requirements. Air compressors and
vacuum pumps.

BS EN ISO 2151 : 2008

Acoustics - Noise test code for compressors and vacuum pumps - Engineering
method (grade 2)

BS EN 60204-1 : 2018

Safety of machinery. Electrical equipment of machines. General requirements.

BS EN IEC 61000-6-2 : 2019

Electromagnetic compatibility (EMC) - Generic standards. Immunity standard
for industrial environments.

BS EN IEC 

6

1000-6-4 : 2019

Electromagnetic compatibility (EMC) - Generic standards. Emission standard
for industrial environments.

BS EN 

ISO 

13849-1 : 2015 

(1)

Safety of machinery. Safety-related parts of control systems. General principles
for design.

(1)

In case control systems are integrated.

Legal person authorized to compile the technical file 
and importer in the UK 
(if the manufacturer is not located in the UK):

Busch (UK) Ltd
30 Hortonwood
Telford - UK

Busch Manufacturing Korea, Ltd.

 

189-51, Soicheon-ro, Majang-myun
Icheon-si, Gyunggi-do, 467-813

Republic of Korea

Icheon-si

, 14.05.2021

Seung-hwa Yoo, General Director

Summary of Contents for COBRA BC 0101 G

Page 1: ...0870704904 0004_en Original instructions Modi cations reserved 20 10 2021 Instruction Manual COBRA Screw Vacuum Pumps BC 0101 G Get technical data instruction manuals service kits...

Page 2: ...e system 13 Switching the system off 13 Maintenance 13 Maintenance program 14 Weekly 14 Monthly 14 Yearly 14 Every 16 000 hours of operation at the latest after 4 years 14 Lock Out Tag Out procedure 1...

Page 3: ...control Interface CWC Cooling water connections TIC Tool interface connection HC Handpad connection EB Eye bolts CP PLC box PB Start Stop button PL Power led ES Warning Alarm led OSG Oil sight glass...

Page 4: ...erned the vacuum pump is suitable for evacuation of a 300 liters tank The vacuum pump is not suitable for continuous duty at a pressure more or equal than 150 hPa mbar Caution the operating cycle of 1...

Page 5: ...d the design level Example BC 0101 G BC standard version 0101 100 m3 h G Design Safety Intended use DEFINITION To rule out any misunderstanding the term handling of the vacuum pump covers transport st...

Page 6: ...wer supply l Switch off the water quick connections inlet first then outlet l Put the label or warning board Maintenance processing on or next to the pump Safety Lockout procedure l Take off the label...

Page 7: ...rs and corresponding actions Without this form duly completed and signed by a legally responsible person the pump should not be disassembled l Proceed to disassembly of the vacuum pump Please make sur...

Page 8: ...cuum pump is equipped with accessories that could influence the centre of gravity this must be taken into account when lifting and a belt must additionally be attached to a specific point l Fasten the...

Page 9: ...n and start up Necessary installation instructions CAUTION If the necessary installation instructions are not followed and particularly in the case of inadequate cooling Risk of damage to and total de...

Page 10: ...e case of long intake lines the line cross section should be larger than the intake flange to prevent a drop in the performance of the vacuum pump If you have any doubts contact your Busch representat...

Page 11: ...OBRA BC 0101 G vacuum pumps are always delivered without oil see the chapter Oil types for information on the recommended oils l Prepare the quantity of oil specified in the table Oil quantity Oil fil...

Page 12: ...owmeter must be connected in such a way that switching on leads to an alarm and stopping of the vacuum pump when the flow drops below 0 3 l min Saving the operating parameters As soon as the vacuum pu...

Page 13: ...if the pump is shut down for a longer period of time Drain the cooling water u Pull off the connections for the inlet and outlet of the cooling water u Drain the cooling water completely u If necessa...

Page 14: ...u Make sure that the operating room is clean and free of dust clean if necessary l Make sure that the vacuum pump has been switched off and that it cannot be switched on again accidentally l Check the...

Page 15: ...s also a danger to the environment Wear protective clothing when replacing contaminated oil Contaminated oil must be treated specially and must be disposed of according to applicable regulations Drain...

Page 16: ...collect it in a container l Dispose of the condensate according to applicable environmental protection regulations l Check the sound absorber regularly and clean it if necessary Checking the leak pro...

Page 17: ...tamination must be documented in a declaration of decontamination Declaration of Decontamina tion which can be downloaded from www buschvacuum com Dispose of the used oil and condensate according to a...

Page 18: ...ntaminated or polluted oil can lead to hazardous pump conditions which could cause personal injury Oil quantity The quantity of oil specified in the following table is of informative nature only Check...

Page 19: ...er pressure bar 2 5 Cooling water temperature C 10 25 Weight approx kg 117 Technical data BC0101G NW 0090 A Nominal suction capacity m3 h cfm 90 53 Ultimate pressure hPa mbar mTorr 0 01 7 5 Nominal mo...

Page 20: ...Safety of machinery Basic concepts general principles of design EN ISO 13857 2019 Safety of machinery Safety distances to prevent hazard zones being reached by the upper and lower limbs EN 1012 1 201...

Page 21: ...Basic concepts general principles of design Risk assess ment and risk reduction BS EN ISO 13857 2019 Safety of machinery Safety distances to prevent hazard zones being reached by the upper and lower l...

Page 22: ...Note...

Page 23: ...Note...

Page 24: ...Italy info busch it Japan info busch co jp Korea busch busch co kr Malaysia busch busch com my Mexico info busch com mx Netherlands info busch nl New Zealand sales busch co nz Norway post busch no Per...

Reviews: