Removal from service
Temporary removal from service
Before disconnecting the intake and exhaust lines and switching off the
cooling water lines, make sure that the lines have adjusted to
atmospheric pressure
Recommissioning
l
Make sure that the various protective elements, stoppers or
adhesive tapes have been removed
l
Switch on the vacuum pump by following the procedure described
in the chapter “Installation and start-up”
Dismantling and disposal
DANGER
If the vacuum pump has pumped gases that were contaminated
with foreign bodies that are hazardous to health, the oil and con-
densate are also contaminated with these foreign bodies.
These foreign bodies can penetrate into pores, openings and other
internal parts of the vacuum pump.
There is a health hazard when dismantling the vacuum pump.
There is also a danger to the environment.
Protective clothing must be worn when dismantling the vacuum
pump.
Prior to shipping, the vacuum pump must imperatively be decon-
taminated and the degree of contamination must be documented in
a declaration of decontamination (“Declaration of Decontamina-
tion”), which can be downloaded from www.buschvacuum.com.
Dispose of the used oil and condensate according to applicable
environmental protection regulations.
When the product has reached the end of its lifetime:
–
decontaminate the vacuum pump
CAUTION
Dismantling work must be carried out by authorised personnel.
Before work begins, the operator of the vacuum pump must fill in a
form or a “Declaration of Decontamination” that provides
information on possible dangers and appropriate measures.
If this form has not been filled in completely and signed, the
vacuum pump may not be dismantled.
–
drain the oil
u
dispose of the oil according to local environmental protection
regulations
–
begin dismantling the vacuum pump
CAUTION
Wear protective clothing when carrying out dismantling work.
u
dispose of the vacuum pump as scrap metal
–
dispose of the individual parts of the machine according to local
regulations
A lithium battery is present inside the PLC:
–
eliminate the lithium battery according to local and national
regulations in place, relating to environment