Mounting / Installation
Mounting / Installation
4.2
Mounting the Unit
The unit comes with a track for easy wall mounting. Before mounting the
unit, please read the following requirements:
•
The wall must be stable enough to hold the unit.
•
An outlet with contact protection for electricity and a water drainage
connection should both be in close proximity.
•
Make sure to check the wall for electrical wiring and water and gas pi-
pes before drilling as they may get damaged.
•
To protect the boiler from contamination, place protective covers over
all connections. Please remove these only at the appropriate installa-
tion stage.
Next, measure the wall intended as the loca-
tion of the unit. Follow the measurements of
the unit and the minimum safety distances. If
the unit is to be attached to an existing chim-
ney, use the emissions connection, including
the elbow as the point of reference.
Mark the drilling positions for the mounting
track and drill using an 8 mm bit.
Place the plastic expansion studs in the wall
and fasten the track to the wall with the
screws. Use a level to make sure the track is
straight and then screw it tightly to the wall.
Hang the unit to the mounted track and make
sure it is mounted firmly.
Use the setting screws at the bottom of the
back of the boiler to align it parallel to the wall.
Check one more time with the level to make
sure the boiler is straight.
3
2
0
Fig. 11 Wall Track
8
5
Fig. 12 Wall Mount (mm)
- 14 -
Gebr. Bruns GmbH is not responsible for typographical errors or technical inaccuracies and reserves the right to make adjustments.
Gebr. Bruns GmbH
•
Hauptstraße 200
•
26683 Saterland
•
Tel.: + 49 (0) 44 92 / 92 46-0
•
Fax: + 49 (0) 44 92 / 71 41
www.bruns-heiztechnik.de
•