31
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
12.3. Technical parameters
Model
PyroBurn
Lambda 25
PyroBurn
Lambda 30
Heat output
kW
12
÷
25
15÷30
Heating surface m
2
150-250
150-350
Height Н mm
1285
1435
Width L/ Depth D mm
675/1130
765/1130
Mantle volume
L
75
85
Combustion chamber volume
L
98
143
Combustion chamber resistance Pa/mbar
12/0.12
11/0.11
Required chimney draught
Pa
10
÷
15
10÷15
Power supply / consumption V/Hz / W
230/50/200
230/50/200
Loading door size mm
400/200
490/260
Max. length of firewood logs mm
500
500
Recommended fuel
wood, humidity 15-
20%; wood briquettes
wood, humidity 15-
20%; wood briquettes
Fuel consumption for heating season m
3
10-20
~15÷23
Burning time partial/full load h
10/6
14/8
Operating temp. range / Max.temp. °С
65÷85/95
65÷85/95
Exhaust gas temperature (operat. mode) °С
130÷150
130÷150
Operating pressure bar
3
3
Weight kg
490
610
Cold water inlet А, mm
G1¼”/160
G1¼“/170
Hot water outlet B, mm
G1¼”/1180
G1¼“/1325
Safety line sleeve
K
P
P
Safety heat evacuator inlet/outlet E, mm
R½”/1090
R½“/1160
Flue
F, mm
ø150/1000
ø150/1075
J, mm
338
382
Cleaning opening
Upper
O1, mm
400/140
455/120
Lower O2, mm
350/140
350/140
Step-regulated
motor / servo-actuator/
M
1, mm
595
665
M2, mm
440
515
Drain
Y, mm
R
½”/87
R½“/100
Air intake
Primary air V1, mm
595
655
Secondary air V2, mm
440
505
Draught fan W, mm
815
890
Buffer tank volume
L
1000
1956
Lambda sond
l
P
P
Sensor for exhaust emissions
T
P
P
Lever for cleaning smoke tubes
S
P
P
Eyepiece for viewing the combustion
P
P
P
Controller
U
P
P
Summary of Contents for Lambda series
Page 2: ......
Page 32: ...TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE 32...
Page 34: ......
Page 35: ......