III. Venting / Air Intake Piping
TABlE 1: AIR INTAkE / VENT SySTEM OPTIONS
WARNING
Do not use this boiler with galvanized, Type 04 or Type 1 stainless steel, non metallic or any other
non Al9-4C
®
based vent systems.
Do not use a barometric damper or drafthood with this appliance.
Do not use vent dampers with this boiler.
Moisture and ice may form on surfaces around termination. To prevent deterioration, surfaces should
be in good repair (sealed, painted, etc.).
This appliance needs fresh air for safe operation and must be installed so there are provisions for
adequate combustion and ventilation air.
Do not reduce size of air intake pipe.
Read, understand and follow combustion air instruction restrictions contained in the Pre-Installation
instructions of this manual.
Do not operate appliance where gasoline or other flammable vapors or liquids, or sources of hydro-
carbons (i.e. bleaches, cleaners, chemicals, sprays, paint removers, fabric softeners, etc.) are used,
stored and/or present in the air.
When installing vent pipe through chimney, no other appliance can be vented into the chimney.
Do not exceed maximum vent/air intake lengths. Refer to Table 4.
Option
Description
Additional
Vent Kit
Required
Part Number
Installation
Drawing and
Specification
(See Section)
1. Separate
Horizontal
Direct Vent (sealed combustion) with both the vent pipe and
air intake pipe terminating horizontally (through a sidewall)
with individual penetrations for the vent and air intake piping
and terminals.
No
See Table 2
D.
2. Separate
Vertical
Direct Vent (sealed combustion) with both the vent pipe and
air intake pipe terminating vertically (through the roof) with
individual penetrations for the vent and air intake piping and
terminals.
No
See Table 2
E.
3. Combination
Horizontal
Direct Vent (sealed combustion) with the vent pipe and air
intake pipe joining at a common terminal and terminating
horizontally (through a sidewall up to 15” thick) with only
one penetration.
Yes
3 - 6 Section
(61106012)
F.
4. Combination
Vertical
Direct Vent (sealed combustion) with the vent pipe and air
intake pipe joining at a common terminal and terminating
vertically (through the roof) with only one penetration.
Yes
3 - 4 Section
(100222-01)
5 - 6 Section
(100223-01)
G.
5. Indoor Air
Power Vent - Air used for combustion is provided from within
the building.
No
-----
H.
6. Optional
Separate
Horizontal
Direct Vent (sealed combustion) with both the vent pipe and
air intake pipe terminating horizontally (through a sidewall)
with individual penetrations for the vent and air intake piping
and terminals.
No
See Table 2
I.
Summary of Contents for SCG
Page 5: ...Figure 2 Dimensions...
Page 13: ...13 Figure 4A Recommended Separate Horizontal Vent Air Intake Installation...
Page 14: ...14 Figure 4B Alternate Separate Horizontal Vent Air Intake Installation...
Page 15: ...15 Figure 5A Separate Horizontal Vent Air Intake Terminal Configuration SCG 3 thru 7...
Page 16: ...16 Figure 5B Separate Horizontal Vent Air Intake Terminal Configuration SCG 8 and 9...
Page 19: ...19 Figure 7 Attic Offset Figure 6 Vertical Vent Installation...
Page 22: ...22 Figure 9 Vertical Air Intake Piping...
Page 25: ...25 Figure 10 Combination Horizontal Vent Air Installation SCG 3 thru 6...
Page 26: ...26 Figure 11 Combination Horizontal Vent Air Terminal Installation SCG 3 thru 6...
Page 38: ...38 Figure 12 Recommended Separate Horizontal Vent Installation...
Page 39: ...39 Figure 13 Alternate Separate Horizontal Vent Installation...
Page 44: ...44 Figure 22 Optional Separate Horizontal 4 Vent Terminal Installation Indoor Air...
Page 48: ...48 Figure 25 Recommended Water Piping for Circulator Zoned Heating Systems...
Page 49: ...49 Figure 26 Recommended Water Piping for Zone Valve Zoned Heating Systems...
Page 54: ...54 Figure 28 Internal Boiler Wiring Schematic Diagram...
Page 57: ...57 Figure 30 System Wiring Schematic for Single Zone Space Heating Only...
Page 59: ...59 Figure 32 Circulator Zoned System Wiring Schematic...
Page 60: ...60 Figure 33 Zone Valve Zoned System Wiring Schematic...
Page 61: ...61 Figure 34 Different Manufacturer s Zone Valve Connections to Honeywell R8889...
Page 63: ...63 Figure 35 Modular Boiler Gas Piping...
Page 65: ...65 Figure 36 Operating Instructions...
Page 68: ...68 Figure 38 Troubleshooting Guide Honeywell Electronic Ignition Troubleshooting Guide...
Page 73: ...73 Figure 44 Flue and Burner Cleanout 1 Burner...
Page 75: ...75 THIS PAGE LEFT INTENTIONALLY BLANK...
Page 76: ...76...
Page 77: ...77...
Page 80: ...80...
Page 82: ...82...
Page 84: ...84...
Page 86: ...86...
Page 88: ...88...
Page 90: ...90...
Page 94: ...94 SERVICE RECORD DATE SERVICE PERFORMED...