![burmeier ECONOMIC II 51.0714.33 Instruction Manual Download Page 25](http://html1.mh-extra.com/html/burmeier/economic-ii-51-0714-33/economic-ii-51-0714-33_instruction-manual_2832791025.webp)
U
pUte za UporabU za krevet za njegU bolesnika
eConoMiC ii · i
nstrUCtion
M
anUal for
n
Ursing
b
ed
eConoMiC ii
25
Uzglavlje
Head section
Stalak
Trapeze pole
n
Mrežni kabel prije svake vožnje kreveta
objesite o držač mrežnog kabela inače se
može potrgati, može se prijeći preko njega,
zgnječivši otkinuti ili oštetiti. Ta oštećenja
mogu dovesti do električnih opasnosti i
funkcionalnih smetnji.
DržAČ MrEžNOG kABElA
Držač mrežnog kabela nalazi se bočno na
okviru ležne plohe na području podnožja.
n
Maksimalna nosivost stalka na njegovom
prednjem kraju iznosi 75 kg.
STAlAk
Stalak montiran na krevetu omogućuje
bolesniku jednostavniji ulazak i izlazak.
U oba kuta okvira ležne plohe, na strani glave,
nalaze se dvije okrugle čahure stalka.
[16]
.
Čahura stalka ima na gornjoj strani otvor
[c]
koji zajedno sa zatikom
[b]
ograničava
zakretno područje stalka. Stalak montirajte na
strani kreveta na kojoj bolesnik ulazi i izlazi.
Montiranje
F
Stalak
[2]
utaknite u čahuru. Metalni zatik
[b]
se treba nalaziti u otvoru
[c]
čahure.
Uklanjanje
F
Stalak izvucite ravno prema gore iz čahure.
Zakretno područje stalka
Nemojte zakretati stalak izvan kreveta.
Postoji opasnost da se krevet prevrne zbog
potezanja stalka.
Metalni zatik stalka mora se uvijek nalaziti
u otvoru.
n
The power cable must be secured in the
power cable holder provided, before
moving the bed, otherwise it might be
damaged by stretching, by running over
and squeezing.
POWEr CaBlE hOlDEr
The power cable holder is located sideways
on the reclining surface frame near the foot
section.
n
The maximum load of the trapeze pole is
75 kg at the front end.
TraPEzE POlE
The trapeze pole attached to the bed makes it
easier for the patient to get into and out of
bed.
In both corners of the head section of the
reclining surface frame are two trapeze pole
sockets
[16]
. The trapeze pole socket has a
notch at the top
[c]
, which together with the
metal pin
[b]
restricts the swivel range of the
trapeze pole. The trapeze pole should be
installed on the side where the patient gets in
and out of bed.
Attaching
F
Insert the trapeze pole
[2]
into the socket.
The metal pin
[b]
must be in the notch
[c]
of
the socket.
removal
F
Pull the trapeze pole straight up out of the
socket.
Trapeze pole swivel range
Do not swivel the trapeze pole outside of
the bed. There is a danger that through the
pull, the bed will tip over.
The metal pin must always be in the notch
of the socket.