![Bürkert 8695 Operating Instructions Manual Download Page 16](http://html1.mh-extra.com/html/burkert/8695/8695_operating-instructions-manual_2831914016.webp)
16
Technicaldata
6.8
electrical data
Warning!
Only circuits with limited power may be used for UL approved components according to “NEC Class 2”.
6.8.1
electrical data without bus control 24 V Dc
Protection class
3 as per DIN EN 61140 (VDE 0140-1)
Connections
Circular plug-in connector (M12 x 1, 8-pole)
Pilot valve
Operating voltage
24 V DC ± 10% - max. residual ripple 10 %
Power input
max. 1 W
Output
max. 100 mA per output
Display
max. 20 mA per illustrated illuminated display (LED)
6.8.2
electrical data with as-interface bus control
Protection class
3 as per DIN EN 61140 (VDE 0140-1)
Connections
Circular plug-in connector (M12 x 1, 4-pole)
Profile
S-B.A.E. (A/B slave, max. 62 slaves/master)
Operating voltage
29.5 V – 31.6 V DC (according to specification)
Outputs
Max. switching capacity
1 W via AS-Interface
Watchdog function
integrated
Max. power consumption
120 mA
Power consumption input during
normal operation
(after current reduction;
valve + 1 end position reached) 90 mA
6.8.3
electrical data with Devicenet bus control
Protection class
3 as per DIN EN 61140 (VDE 0140-1)
Connections
Circular plug-in connector (M12 x 1, 5-pole)
Operating voltage
11 V – 25 V
Max. power consumption
< 80 mA
Output Pull-in current current
≤
50 mA
Holding current
≤
30 mA
english