![Bürkert 8695 Operating Instructions Manual Download Page 15](http://html1.mh-extra.com/html/burkert/8695/8695_operating-instructions-manual_2831914015.webp)
15
Technicaldata
6.6.3
ul additional label
Example:
Type 4X enclosure
NEC Class 2 only
Supply voltage: 24 V
Supply voltage device
Circuit with limited power
Degree of protection
Figure 5:
UL additional label (example)
6.7
pneumatic data
Control medium
neutral gases, air
Quality classes in accordance with ISO 8573-1
Dust content
Class 7
max. particle size 40 µm, max. particle density 10 mg/m³
Water content Class 3
max. pressure dew point
- 20 °C or min. 10 °C below the lowest operating temperature
Oil content
Class X
max. 25 mg/m³
Temperature range
-10 – +50 °C
Pressure range
3 – 7 bar
Air output of pilot valve
7 l
N
/ min (for aeration and deaeration)
(Q
Nn
- value according to definition for pressure drop from 7 to 6 bar absolute)
Connections
21xx (Element)
Plug-in hose connector
∅
6 mm / 1/4“
Socket connection G 1/8
20xx (Classic)
Socket connection G 1/8
with M5 connection for connecting to the actuator
english
Type 8695