64
English
SE58
L
Voltage measured on electrode E1.
Form fields when is active the recording of data on the input voltage
(diagnostic value).
Voltage measured on electrode E2.
Form fields when is active the recording of data on the input voltage
(diagnostic value).
Differential voltage between the two electrodes.
Form fields when is active the recording of data on the
input voltage (diagnostic value)
Common mode voltage in the electrodes.
Form fields when is active the recording of data on the input
voltage (diagnostic value).
Noise at low frequency measured on the electrodes.
Form fields when is active the recording of data
on the input signal noise levels (diagnostic value).
Differential low frequency noise measured on the electrodes.
Form fields when is active the
recording of data on the input signal noise levels (diagnostic values).
Low-frequency noise measured input ADC.
Form fields when is active the recording of data on the input
signal noise levels (diagnostic values).
High frequency noise measured input ADC.
Form fields when is active the recording of data on the input
signal noise levels (diagnostic values).
Measured equivalent resistance on the electrode 1.
Form fields when is active the recording of data
on the electrode resistance measurements (diagnostic values).
Measured equivalent resistance on the electrode 2.
Form fields when is active the recording of data
on the electrode resistance measurements (diagnostic values).
Coils excitation current.
Form fields when is active the recording of data related to the sensor excitation circuit
measures (diagnostic value)
Measured resistance of the excitation circuit (coil + cable).
Form fields when is active the recording
of data relative to the sensor excitation circuit measures (diagnostic values).
Temperature measured on the sensor coils (indirect measurement).
Form fields when the data
transmission flag is active relative to the sensor excitation circuit measures (diagnostic values).
Temperature T1 (Board Sensor 1: located close to the amplifier input).
Form fields when the
data transmission flag on board the internal temperature measurement is active (diagnostic values).
Temperature T2 (Board sensor 2: located close to the power supply module).
Form fields
when the data transmission flag on board the internal temperature measurement is active (diagnostic values).
CPU temperature.
Form fields when the data on the board’s internal power supply voltage measurements flag is
ON (diagnostic value).
Primary power supply of CPU.
Form fields when the data on the board’s internal power supply voltage
measurements flag is ON (diagnostic value).
Positive supply voltage of analog circuits.
Form fields when the data on the board’s internal power supply
voltage measurements flag is ON (diagnostic values).
Summary of Contents for B0A1C2B1A4A0
Page 1: ...Type SE58 L Transmitter Operating Instructions...
Page 8: ...7 English SE58 L Dimensions 200 114 164 167 114 180 290 195...
Page 9: ...8 English SE58 L Remote version 142 28 295 120 7 30...
Page 11: ...10 English SE58 L DIMENSIONS STAINLESS STEEL VERSION Compact Version 171 156 186 146...
Page 12: ...11 English SE58 L Separate Version 236 40 7 90 241 55...