background image

 

Technical Data 

 

Installing your Burco boiler 

Before connecting to the power supply 

  Remove all packaging and plastic coating from the appliance  

  Check the unit has not been damaged in any way during transportation. Report any damage to the 

company who sold you the boiler right away. 

  Check the available power supply corresponds to that shown on the rating label of the appliance, which 

must be A.C. (Alternating Current). 

  Ensure the yellow steam cap is removed from the steam vent prior to powering appliance. 

  The location must be frost free. 

 

Connecting to the water supply 

  Connection from the cold water supply to the appliance should only be made by the hose supplied. 

  In hard water areas, it is always advisable to fit an inline filtration unit to limit scale build-up. If you 

have purchased a Burco boiler that does not have a water filter system included, we recommend you 
fit a separate water filter between the boiler and the mains supply. 

  Always  ensure  mains  water  supply  is  turned  off,  or  localised  isolation  valves  are  closed  before 

attempting to connect boiler to the mains water supply.  

  The inlet water connection to the inlet solenoid valve is 

¾” BSP, this should be connected to the mains 

water supply via an accessible isolating tap. 

  The blue pipe connects to the grey fitting which can be found underneath the appliance.  

  Firmly push the blue pipe into the small outlet hole on the grey fitting. 

  Ensure grey connection is screwed tight on the appliance and not leaking. 

  Locate the second grey connection fitting. Connect the other end of the blue pipe to this. This second 

grey connection fitting is connected to the mains water supply forming a cold water feed from the 
mains water supply to the Burco boiler. 

  Do not use old water hoses.  

Model 

CT5L 

CT10L, PB 

CT20L 

CT20L TT 

SL5L, PB 

SL10L,PB   SL10L EH 

Height (mm) 

457 

578 

 695 

518 

627  

668  

Width (mm) 

358 

215  

Depth (mm) 

464 

 373 

Capacity (Litres) 

10 

20 

10 

10 

Weight (Kg) 

11 

12 

13 

14 

10 

11 

11.5 

Ambient Temperature 

5°C 

– 30°C 

Water Inlet Pressure 

– 8 (Bar) 

Voltage 

220-240V (50/60Hz) 

Power Rating 

3kW 

6kW 

3kW 

Summary of Contents for CT10L

Page 1: ...End Southampton SO30 2DF Aftersales Tel 0344 879 3470 www burco co uk Please keep these instructions in a safe place 08 54070 0 Jan 19 These instructions cover the following Burco models Burco Filtrat...

Page 2: ...shooting 15 Spare Replacement Part information 15 Frequently asked questions FAQ s 16 About my product Please take some time to complete the information below it may save time if you need to contact u...

Page 3: ...EGULATIONS BS CODES OF PRACTICE LOCAL AND NATIONAL BUILDING REGULATIONS LOCAL AND NATIONAL WATER REGULATIONS THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED...

Page 4: ...O ACTS AS A VENT FOR THE APPLIANCE UNDER NO CIRCUMSTANCES SHOULD THIS FLEXIBLE HOSE BECOME BLOCKED OR RESTRICTED IN ANY WAY THIS APPLIANCE MUST ONLY BE USED FOR HEATING WATER THE UNIT MUST BE INSTALLE...

Page 5: ...water boiler please contact our Aftersales team on 0344 879 3470 To ensure we can offer you the best possible service please ensure you have the product code and serial number available from page 2 Y...

Page 6: ...d the mains supply Always ensure mains water supply is turned off or localised isolation valves are closed before attempting to connect boiler to the mains water supply The inlet water connection to t...

Page 7: ...fitting a BS 1363 13A fused plug then fit a 13A fuse and tighten the plug cover securely If you are in any doubt consult a qualified electrician Means of isolation with at least 3mm contact separation...

Page 8: ...steam to a sink draining board The flexible hose connected from the over flow also acts as a vent for the appliance Under no circumstances should this flexible hose become blocked or restricted in any...

Page 9: ...s connected to the mains water supply Turn on the mains power and press and hold the power button for 10 seconds The boiler should begin filling and heating Ensure boiler is set to 98 C fully drain th...

Page 10: ...screen lock function If in locked mode the lock logo will blink on the screen for a couple of seconds if any button is pressed Set Time Press MENU SET CLOCK will be highlighted Press MENU to enter th...

Page 11: ...o water is drawn from the boiler in 2 hours the eco mode is engaged The backlight turns off and the only data displayed is the Burco logo along with the time and the status indicator Water should be d...

Page 12: ...nter reset refer to replacement parts Power Down To power down the product the STANDBY button should be held when on the normal operation screen for 10 seconds The shutdown screen will appear and usin...

Page 13: ...0 Drain and flush the de scaling agent from the tank using tap on the front of theappliance 11 FILTERED MODELS ONLY To drain the tank completely locate the drain valve at base picture 4 12 UNFILTERED...

Page 14: ...potential and may invalidate your warranty Disconnect from the electrical supply before cleaning and allow water boiler to cool Do not immerse the water boiler in water or any other liquids and take...

Page 15: ...n be scanned using an iPhone Android and Windows device which will take you to the Burco website Spare Replacement Parts Genuine replacement Burco parts must be fitted If generic non Burco parts are f...

Page 16: ...a Replace filter and reset the filter counter If you need further help see the demonstration video on our website at www burco co uk changefilter 5 The water from the tap is cold a Check appliance is...

Reviews: