background image

10 

 

 

Touch Screen Display (filtered models only):  

The LCD

 

screen will illuminate with the Burco logo.

 

The 

default temperature and the time will flash waiting to be 
set. The  hour  figure  will  flash.   Use  the  scroll  buttons 
and press MENU to set when the correct time is shown. 
To  change  default  temperature,  press  UP/DOWN

 

SCROLL buttons to adjust to required temp.

 

 

 

 

 

Touch Screen Safety Lock:

  

Pressing  and  holding  both  the  MENU  and  the  UP 
SCROLL button for 3 seconds activates the screen lock 
function.  When  the  Screen  Lock  function  is  active 
settings cannot be changed. Press and hold the same 
buttons  to  deactivate  the  screen  lock  function.  If  in 
locked mode, the lock logo will blink on the screen for 
a couple of seconds if any button is pressed.                                            

 

 

 
 

Set Time: 

Press MENU, SET CLOCK will be highlighted. Press MENU to enter the SET CLOCK menu. The time will be 
displayed and the hour value will be flashing. Use the SCROLL buttons to select the correct value then press 
MENU. The minute values will now be flashing. Use the SCROLL buttons again to select the correct values. 
To store the time press MENU button again, this will also take you back to the SET UP menu. To exit the 
SET UP menu press the STANDBY button.

 

 

 

 

 

Set Temperature: 

Use the UP and DOWN buttons to adjust the temperature. Press and hold the UP or Down button for 3 seconds 
before setting desired temperature.  
 

 

 

Screen Settings: 

 

 UP 

 DOWN 

 STANDBY 

 MENU 

STANDBY 

SETTINGS 

                   ECO MODE 

Summary of Contents for CT10L

Page 1: ...End Southampton SO30 2DF Aftersales Tel 0344 879 3470 www burco co uk Please keep these instructions in a safe place 08 54070 0 Jan 19 These instructions cover the following Burco models Burco Filtrat...

Page 2: ...shooting 15 Spare Replacement Part information 15 Frequently asked questions FAQ s 16 About my product Please take some time to complete the information below it may save time if you need to contact u...

Page 3: ...EGULATIONS BS CODES OF PRACTICE LOCAL AND NATIONAL BUILDING REGULATIONS LOCAL AND NATIONAL WATER REGULATIONS THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED...

Page 4: ...O ACTS AS A VENT FOR THE APPLIANCE UNDER NO CIRCUMSTANCES SHOULD THIS FLEXIBLE HOSE BECOME BLOCKED OR RESTRICTED IN ANY WAY THIS APPLIANCE MUST ONLY BE USED FOR HEATING WATER THE UNIT MUST BE INSTALLE...

Page 5: ...water boiler please contact our Aftersales team on 0344 879 3470 To ensure we can offer you the best possible service please ensure you have the product code and serial number available from page 2 Y...

Page 6: ...d the mains supply Always ensure mains water supply is turned off or localised isolation valves are closed before attempting to connect boiler to the mains water supply The inlet water connection to t...

Page 7: ...fitting a BS 1363 13A fused plug then fit a 13A fuse and tighten the plug cover securely If you are in any doubt consult a qualified electrician Means of isolation with at least 3mm contact separation...

Page 8: ...steam to a sink draining board The flexible hose connected from the over flow also acts as a vent for the appliance Under no circumstances should this flexible hose become blocked or restricted in any...

Page 9: ...s connected to the mains water supply Turn on the mains power and press and hold the power button for 10 seconds The boiler should begin filling and heating Ensure boiler is set to 98 C fully drain th...

Page 10: ...screen lock function If in locked mode the lock logo will blink on the screen for a couple of seconds if any button is pressed Set Time Press MENU SET CLOCK will be highlighted Press MENU to enter th...

Page 11: ...o water is drawn from the boiler in 2 hours the eco mode is engaged The backlight turns off and the only data displayed is the Burco logo along with the time and the status indicator Water should be d...

Page 12: ...nter reset refer to replacement parts Power Down To power down the product the STANDBY button should be held when on the normal operation screen for 10 seconds The shutdown screen will appear and usin...

Page 13: ...0 Drain and flush the de scaling agent from the tank using tap on the front of theappliance 11 FILTERED MODELS ONLY To drain the tank completely locate the drain valve at base picture 4 12 UNFILTERED...

Page 14: ...potential and may invalidate your warranty Disconnect from the electrical supply before cleaning and allow water boiler to cool Do not immerse the water boiler in water or any other liquids and take...

Page 15: ...n be scanned using an iPhone Android and Windows device which will take you to the Burco website Spare Replacement Parts Genuine replacement Burco parts must be fitted If generic non Burco parts are f...

Page 16: ...a Replace filter and reset the filter counter If you need further help see the demonstration video on our website at www burco co uk changefilter 5 The water from the tap is cold a Check appliance is...