background image

12 

 

Heating up: 

HEATING  will  flash  on  controller  screen  during  the 
heating  up  period.  LOW  TEMP  may  be  shown  on  the 
screen  during  this  time.  When  selected  temperature  is 
achieved 

– READY is shown.

 

 

 

 

 

Filling: 

Once the INITIAL SET UP is complete, the filling process 
will start. The LCD Screen will show the word FILLING. 
After the filling is complete, the heating will start until it 
reaches the set temperature. The LCD Screen will show 
the word HEATING.

 

 
 
 
 
 

Filter Life (Filtration models only): 

During operation, the bars fill to represent filter usage. Once 
exhausted,  all  the  bars  are  solid  and  the  fault  code  for 
changing the filter is displayed. The unit should be powered 
down.  Filters  replaced  and  filter  counter  reset  (refer  to 
replacement parts).

 

 

 
 

Power Down: 

To power down the product, the STANDBY button should be 
held  when  on  the  normal  operation  screen for  10  seconds. 
The  shutdown  screen  will  appear  and  using

 

the  scroll 

buttons, 

‘Yes’ should be selected by

 

pressing MENU. The unit 

will then shutdown.

 

 

 

 

 

Tap function: 

The  tap  can  be  changed  between  a  controllable  and  constant 

flow. For ‘Controllable’ flow, simply pull the plastic handle away 
from you to dispense water and release to stop, see image 1. If 
you turn the plastic tap handle through 180 degrees, the tap will 

be in ‘Constant’ mode, see image 2. Now when you pull the tap 

towards you, it will remain locked downwards in an ‘open’ state 
until  you  lift  the  black  handle  back  upwards  to  stop.  The  tap 
function  is  the  same  on  tap  models  on  both  our  Filtered  and 
Unfiltered boilers. 

Always take care when operating the tap as the water will 

be boiling hot.

 

 

 

1. 

2. 

Summary of Contents for CT10L

Page 1: ...End Southampton SO30 2DF Aftersales Tel 0344 879 3470 www burco co uk Please keep these instructions in a safe place 08 54070 0 Jan 19 These instructions cover the following Burco models Burco Filtrat...

Page 2: ...shooting 15 Spare Replacement Part information 15 Frequently asked questions FAQ s 16 About my product Please take some time to complete the information below it may save time if you need to contact u...

Page 3: ...EGULATIONS BS CODES OF PRACTICE LOCAL AND NATIONAL BUILDING REGULATIONS LOCAL AND NATIONAL WATER REGULATIONS THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED...

Page 4: ...O ACTS AS A VENT FOR THE APPLIANCE UNDER NO CIRCUMSTANCES SHOULD THIS FLEXIBLE HOSE BECOME BLOCKED OR RESTRICTED IN ANY WAY THIS APPLIANCE MUST ONLY BE USED FOR HEATING WATER THE UNIT MUST BE INSTALLE...

Page 5: ...water boiler please contact our Aftersales team on 0344 879 3470 To ensure we can offer you the best possible service please ensure you have the product code and serial number available from page 2 Y...

Page 6: ...d the mains supply Always ensure mains water supply is turned off or localised isolation valves are closed before attempting to connect boiler to the mains water supply The inlet water connection to t...

Page 7: ...fitting a BS 1363 13A fused plug then fit a 13A fuse and tighten the plug cover securely If you are in any doubt consult a qualified electrician Means of isolation with at least 3mm contact separation...

Page 8: ...steam to a sink draining board The flexible hose connected from the over flow also acts as a vent for the appliance Under no circumstances should this flexible hose become blocked or restricted in any...

Page 9: ...s connected to the mains water supply Turn on the mains power and press and hold the power button for 10 seconds The boiler should begin filling and heating Ensure boiler is set to 98 C fully drain th...

Page 10: ...screen lock function If in locked mode the lock logo will blink on the screen for a couple of seconds if any button is pressed Set Time Press MENU SET CLOCK will be highlighted Press MENU to enter th...

Page 11: ...o water is drawn from the boiler in 2 hours the eco mode is engaged The backlight turns off and the only data displayed is the Burco logo along with the time and the status indicator Water should be d...

Page 12: ...nter reset refer to replacement parts Power Down To power down the product the STANDBY button should be held when on the normal operation screen for 10 seconds The shutdown screen will appear and usin...

Page 13: ...0 Drain and flush the de scaling agent from the tank using tap on the front of theappliance 11 FILTERED MODELS ONLY To drain the tank completely locate the drain valve at base picture 4 12 UNFILTERED...

Page 14: ...potential and may invalidate your warranty Disconnect from the electrical supply before cleaning and allow water boiler to cool Do not immerse the water boiler in water or any other liquids and take...

Page 15: ...n be scanned using an iPhone Android and Windows device which will take you to the Burco website Spare Replacement Parts Genuine replacement Burco parts must be fitted If generic non Burco parts are f...

Page 16: ...a Replace filter and reset the filter counter If you need further help see the demonstration video on our website at www burco co uk changefilter 5 The water from the tap is cold a Check appliance is...