Page 37
29877 121302
TROUBLESHOOTING (cont.)
Screen Displayed
Possible Cause
Troubleshooting Procedures
1.
SMART FUNNEL
not fully inserted
into the funnel rails.
2. Not using a
SMART FUNNEL
, and
the
FUNNEL DETECT
function is ac-
tivated (on).
1. Water temperature in the tank
does not meet the
SET READY TEM-
PERATURE.
1. Brew funnel was not removed
after the previous brew cycle was
finished.
1. Brew funnel was moved out of
position after the brew cycle was
started.
Position the funnel so that the sen-
sor is directly beneath the sensor
coil on the brewer.
Disable the
FUNNEL DETECT
func-
tion. See page 32 for procedure.
(a) Wait for the brewer to heat to the
proper temperature.
(b) Disable the
BREW LOCKOUT
function. See page 10 for proce-
dure.
Remove funnel, check contents, and
insert back into the funnel rails.
OR
Press
BREW
to start a brew cycle
without removing the funnel.
To resume brewing, correctly posi-
tion the funnel and press
BREW
again. The brew cycle will resume
from the point it was interrupted.
OR
Press
ON/OFF
to terminate the cycle.