Note:
If an SRN or other reference code is displayed, suspect a loose adapter or cable connection.
Review the procedures for the part that you replaced to ensure that the new part is installed correctly.
If you cannot correct the problem, collect all SRNs or any other reference code information that you
see. If the system will not boot or you have no login prompt go to
Problems with loading and starting
.
Note:
If you received an SRN or any other reference code when you attempted to start the system,
you can learn more about these codes in
If the terminal type is requested, you must use the
Initialize Terminal
option on the
Function
Selection
menu to initialize the operating system before you can continue.
8.
From the Function Selection menu, select
Advanced Diagnostics Routines
. Press Enter.
9.
From the Diagnostic Mode Selection menu, select
System Verification
. Press Enter.
10.
When the Advanced Diagnostic Selection menu appears, select
All Resources
, or test only the part
you replaced, and any devices that are attached to the part you replaced, by selecting the diagnostics
for the individual part. Press Enter.
11.
Did the
Testing Complete, No trouble was found
message appear?
No:
There is still a problem. Contact your service provider.
♦
Yes:
♦
12.
If you changed the service processor or network settings, as instructed in previous procedures,
restore the settings to the value they had prior to servicing the system.
13.
If the indicator lights are still on, follow these steps:
Select
Identify and Attention Indicators
from the
Task Selection
menu to turn off the
system attention and indicator lights. Press Enter.
a.
Select
Set System Attention Indicator to NORMAL
and press Enter.
b.
Select
Set All Identify Indicators to NORMAL
and press Enter.
c.
Choose
Commit
.
Note:
This changes the system attention and identify indicators from the
Fault
state to the
Normal
state.
d.
Exit to the command line.
e.
14.
Parent topic:
Verify the installed part on a Linux system or logical partition (run AIX diagnostics)
Verify the presence of an installed part using Hardware Management
Console (HMC)
Use these instructions to verify an installed part using the Hardware Management Console (HMC). If you have
reference codes, symptoms, or location codes that you used during the service action, locate the records to
use during this procedure.
Use this procedure to update your HMC records after you have completed a service action on your server. If
you have reference codes, symptoms, or location codes that you used during the service action, locate the
records to use during this procedure.
At the HMC, examine the service action event log for any open service action events. See
for details.
1.
Are there any service action events that are open?
No
: If the system attention LED is still on, use the HMC to turn off the LED. See
This ends the procedure.
♦
Yes
: Continue with the next step.
♦
2.
Control panel
Verify the presence of an installed part using Hardware Management Console (HMC)
79
Summary of Contents for Escala PL 1650R-L+
Page 1: ...Hardware Information Control panel ESCALA POWER5 REFERENCE 86 A1 30EW 00...
Page 2: ...BLANK...
Page 34: ...Control panel 28 Replace the control panel signal cable...
Page 41: ...Control panel Stop the system or logical partition 35...
Page 59: ...Control panel Open the model ESCALA PL 250R VL or ESCALA PL 450R XS service access panel 53...
Page 89: ...BLANK...
Page 90: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE 86 A1 30EW 00 REFERENCE...