TC-Double (+)
9.5 Heat exchanger
9.5.1 Heat exchanger description
The energy content of the sample gas and the required cooling capacity of the gas cooler is determined by three parameters: gas
temperature
ϑ
G
, dew point
τ
e
(moisture content) and volume flow v. The outlet dew point rises with increasing energy content of
the gas. The following limits for the maximum flow are specified for a standard operating point of
τ
e
= 50 °C and
ϑ
G
= 70 °C. Indic-
ated is the maximum flow v
max
in Nl/h of cooled air, so after moisture has condensed. Values may differ for other dew points and
gas inlet temperatures. However, the physical facts are so vast we decided to omit the illustration. Please contact our experts for
clarification or refer to our design program.
9.5.2 Heat exchanger overview
TC-Double
Heat exchanger
2x PTS
2x PTS-I
2)
2x PTG
2x PTG-I
2)
2x PTV
2x PTV-I
2)
Version/Material
Stainless steel
Glass
PVDF
Flow rate v
max
1)
450 Nl/h
250 Nl/h
250 Nl/h
Inlet dew point
τ
e,max
1)
70 °C
70 °C
70 °C
Gas inlet temperature
ϑ
G,max
1)
180 °C
140 °C
140 °C
Max. Cooling capacity Q
max
310 kJ/h
215 kJ/h
295 kJ/h
Gas pressure p
max
3 bar
(160 bar on request)
3 bar
2 bar
Pressure drop Δp (v=150 L/h) total
20 mbar
20 mbar
20 mbar
Dead volume V
tot
total
59 ml
59 ml
115 ml
Gas connections (metric)
6 mm
GL 14 (6 mm)
3)
DN 4/6
Gas connections (US)
1/4"
GL 14 (1/4")
3)
1/4"-1/6"
Condensate out connections (metric)
G3/8
GL 25 (12 mm)
3)
G3/8
Condensate out connections (US)
NPT 3/8"
GL 25 (1/2")
3)
NPT 3/8"
1)
Max. cooling capacity of the cooler must be considered.
2)
Models marked I have NPT threads or US tubes, respectively.
3)
Gasket inside diameter.
TC-
Heat exchanger
2x PTG-2
2x PTG-2-I
2)
2x PTV-2
2x PTV-2-I
2)
Version/Material
Glass
PVDF
Flow rate v
max
1)
250 Nl/h
250 Nl/h
Inlet dew point
τ
e,max
1)
70 °C
70 °C
Gas inlet temperature
ϑ
G,max
1)
140 °C
140 °C
Max. Cooling capacity Q
max
230 kJ/h
215 kJ/h
Gas pressure p
max
3 bar
2 bar
Pressure drop Δp (v=150 L/h) total
20 mbar
20 mbar
Dead volume V
tot
total
59 ml
115 ml
Gas connections (metric)
GL 14 (6 mm)
3)
DN 4/6
Gas connections (US)
GL 14 (1/4")
3)
1/4"-1/6"
Condensate out connections (metric)
GL 25 (12 mm)
3)
G3/8
Condensate out connections (US)
GL 25 (1/2")
3)
NPT 3/8"
1)
Max. cooling capacity of the cooler must be considered.
2)
Models marked I have NPT threads or US tubes, respectively.
3)
Gasket inside diameter.
42
Bühler Technologies GmbH
BE440021 ◦ 09/2021
Summary of Contents for TC-Double Plus