Technical Data: Flow Meter
Ambient temperature
80 °C
Media temperature max.
150°C
(with part no. 405610 max. 80°C)
Operating pressure max.
4 bar
Head
PTFE
Seal
PTFE
Adjusting screw
PVDF / Viton or
PCTFE / Perfluorelastomer
Metering tube
Borosilicate glass
Float
Hastelloy C 4 or
optional PEEK with iron core
Union nut
PPS fiberglass reinforced
Base plate
PA
Material
Technical Data: Flow Sensor
Protection class
IP 67 DIN 40050
Ambient temperature
- 20 °C bis + 70 °C
Housing material
PBT
Please indicate with order:
Part no.
Description
49 49 019
Flow sensor for metering tube
with ends ø15mm
49 49 021
Flow sensor for metering tube
with ends ø10mm
SM - 6
SM - 6 - V
Dimensions
Please indicate with order:
Part no.
Range*
40 56
99
0 0
air
6 - 60 NL/h
0 1
air
10 - 100 NL/h
0 2
air
25 - 250 NL/h
0 3
air
50 - 500 NL/h
0 4
air
80 - 800 NL/h
0 5
water 0,5 - 5 L/h
0 6
water 1,2 - 12 L/h
0 7
water 2,5 - 25 L/h
0 8
water 4 - 40 L/h
0 9
water 6 - 60 L/h
1 0
special range
0
without needle valve
1
valve PVDF / Viton
2
valve PCTFE / perfluorelastomer
* standard measuring tube; air 20 °C 1,2 bar abs; water 20 °C
we reserve the right to amend specification
Application in explosive atmosphere:
There is no Ex-designation on the type plate of the equipment, because they are not within the scope of Eurepean
Directive 94/9/EC. However the equipment corresponds to the essential requirements of the Directive 94/9/EC.
Therefore they can be used in explosive atmosphere
(Zone 1 , Group IIC).
Observe all cautions in the Installation and Operation Manual.
Schaltpunkt
Switch point
Klemmschraube
Locking screw
Grenzwertschalter/
Flow sensor
Befestigungsring
Locking ring
25
30
10
17
A000060X
SM - 6
ø5,5
205
50
105
G1/4
28
51
27
42
G1/4
A000058X
ø5,5
27
50
105
216
42
G1/4
max.79
28
G1/4
A000059X
200
150
100
50
250
200
150
100
50
250