Please indicate with order
Part no.
Description
40 22 999
Flow meter S-SM 3-1
Endcaps: SS 1.4571
40 23 999
Flow meter S-SM 3-1
Endcaps: titanium
40 24 999
Flow meter S-SM 4
Endcaps: SS 1.4571 / PTFE
40 25 999
Flow meter S-SM 4-1
Endcaps: SS 1.4571
40 26 999
Flow meter S-SM 5
Endcaps: SS 1.4571
we reserve the right to amend specification
Technical Data
Metering range:
See table*
Metering cone:
Glass, Hastelloy, SS or PTFE
Endcaps:
PTFE, SS or titanium
Support:
Bracket made of plastic
Flow meter S-SM 3-1
Air
Water
Media:
Pressure:
+ 1.2 bar abs.
Temperature:
+ 20 °C
+ 20 °C
1,6
-
16 Nl/h
0.25 - 2.5 l/h
4
-
40 Nl/h
0.5 -
5 l/h
6
-
60 Nl/h
1.2 -
12 l/h
10
-
100 Nl/h
2.5 -
25 l/h
25
-
250 Nl/h
4 -
40 l/h
50
-
500 Nl/h
6 -
60 l/h
80
-
800 Nl/h
10 - 100 l/h
Flow meter S-SM 5
Air
Water
Media:
Pressure:
+ 1.2 bar abs.
Temperature:
+ 20 °C
+ 20 °C
1000 - 10000 Nl/h
25 -
250 l/h
1600 - 16000 Nl/h
40 -
400 l/h
2000 - 20000 Nl/h
63 -
630 l/h
3000 - 30000 Nl/h
100 - 1000 l/h
160 - 1600 l/h
250 - 2500 l/h
Flow meter S-SM 4 / S-SM 4-1
Air
Water
Media:
Pressure:
+ 1.2 bar abs.
Temperature:
+ 20 °C
+ 20 °C
250 - 2500 Nl/h
6.3 -
63 l/h
400 - 4000 Nl/h
10 - 100 l/h
500 - 5000 Nl/h
16 - 160 l/h
800 - 8000 Nl/h
25 - 250 l/h
40 - 400 l/h
63 - 630 l/h
T
E
O
O
ype
A
B
C
ØD
ØF
G
H
SW
kg
perating pressure*
perating temperature*
max. at 20°C
max. at 2bar
S-SM 3-1
S-SM 4
S-SM 4-1
S-SM 5
197
17
17
25
5,5
1/4"NPT
27
22
0 9
10 bar
100 °C
368
17
23
50
6
G 1/2"
40
36
2 8
10 bar
100 °C
368
17
23
50
6
G 1/2"
40
36
2 8
10 bar
100 °C
370
25
23
70
6
G 1"
58
46
4
10 bar
100 °C
42
.
68
.
68
.
95
Table of Typical Ranges
operating temperature max. [°C] - 20
*Operating pressure max. [bar] = 10 -
10
Application in explosive atmosphere:
There is no Ex-designation on the type plate of the equipment, because they are not within the scope of European
Directive 94/9/EC. However the equipment corresponds to the essential requirements of the Directive 94/9/EC.
Therefore they can be used in explosive atmosphere
(Zone 1 , Group IIC).
Regard the indications of the Installation- and Operation-Instruction.
A
C
SW
H
E
ØF
ØD
G
B
A000061X