Appendix
15
56
Installation instructions Logamax plus GB142-24/30/45/60 • version 10/2007
Buderus • http://www.buderus.net
We reserve the right to make any changes due to technical modifications!
15.3 Technical specifications
General specifications
Unit
boiler cap.
24 kW
boiler cap.
30 kW
boiler cap.
45 kW
boiler cap.
60 kW
Gas category
Natural gas
Natural gas
Natural gas
Natural gas
Rated thermal load for Natural gas
btu/hr
25,700 – 84,800
31,800 – 106,000 46,000 – 149,000 66,000 – 214,800
Rated heating capacity for heating curve 176/140 °F
(80 – 60 °C)
btu/hr
22,700 – 75,200
28,100 – 91,500
40,600 – 131,500 58,200 – 189,800
Rated heating capacity for heating curve 122/86 °F
btu/hr
25,300 – 83,300
30,700 – 102,400 45,100 – 146,300 64.800 – 211,600
Boiler efficiency rating max. capacity for heating curve
176/140 °F (80 – 60 °C)
%
88
88
88
88
Boiler efficiency rating max. capacity for heating curve
122/86 °F (50 – 30 °C)
%
97
97
97
97
CSA output
btu/hr
76,300
95,400
144,800
178,900
Heating
Max. flow temperature
°F (°C)
194 (90)
194 (90)
194 (90)
194 (90)
Heater water temperature
°F (°C)
86 – 190 (30 –
90), can be set on
BC10 basic
controller
86 – 190 (30 –
90), can be set on
BC10 basic con-
troller
86 – 190 (30 –
90), can be set on
BC10 basic
controller
86 – 190 (30 –
90), can be set on
BC10 basic
controller
Max. operating overpressure of boiler
psi (bar)
43.5 (3)
43.5 (3)
58 (4)
58 (4)
Heat exchanger heating circuit volume
gallons (l)
0.7 (2.5)
0.7 (2.5)
1.0 (3.6)
1.3 (4.7)
Pipe connections
Gas connection
inch
¾” NPT
¾” NPT
¾” NPT
¾” NPT
Heating system water connection
inch (mm)
1.0” NPT (25.4)
1.0” NPT (25.4)
1.0” NPT (25.4)
1.0” NPT (25.4)
Condensate water connection
inch (mm)
Ø 1.3” (Ø 32)
Ø 1.3” (Ø 32)
Ø 1.3” (Ø 32)
Ø 1.3” (Ø 32)
Flue gas values
Condensate water quantity for natural gas G20, 104/86 °F
(40/30 °C)
gallons
per hour
2.6
3.3
4.7
7.1
pH value condensate water
pH
approx. 4.1
approx. 4.1
approx. 4.1
approx. 4.1
Flue gas mass flow rate at full load
g/s
10.0
12.6
19.4
25.9
Flue gas temperature 176/140 °F (80/60 °C), full load
°F (°C)
150 (66)
167 (75)
150 (66)
150 (66)
Flue gas temperature 176/140 °F (80/60 °C), partial load
°F (°C)
135 (57)
137 (58)
135 (57)
135 (57)
Flue gas temperature 122/86 °F (50/30 °C), full load
°F (°C)
113 (45)
118 (48)
96 (36)
96 (36)
Flue gas temperature 122/86 °F (50/30 °C), partial load
°F (°C)
91 (33)
91 (33)
91 (33)
91 (33)
CO
2
content, full load, natural gas G20
%
9.2
9.2
9.3
9.3
CO
2
content,
full load, LPG G31, propane
%
10.0
10.0
10.0
10.0
Standard emission factor CO
mg/kWh
≤
15
≤
15
1
≤
15
≤
15
Standard emissions factor NO
x
mg/kWh
≤
20
≤
20
1
≤
20
≤
20
Free fan unit feed pressure
inch W.C.
(Pa)
up to 0.023
(up to 60)
up to 0.039
(up to 100)
up to 0.054
(up to 140)
up to 0.054
(up to 140)
Flue gas connection
Ø Flue system, dependent on the air in the room
inch (mm)
3 (80)
3 (80)
3 (80)
3 (80)
Ø Flue system, independent of the air in the room
inch (mm)
3/3 (80/80)
parallel
3/3 (80/80)
parallel
3/3 (80/80)
parallel
3/3 (80/80)
parallel
Electric data
main voltage
V, Hz
120, 60
120, 60
120, 60
120, 60
Fuses
amps
5 amps 120V
slow blow
5 amps 120V
slow blow
5 amps 120V
slow blow
5 amps 120V
slow blow
Electrical protection rating
IP X4D
IP X4D
IP X4D
IP X4D
Electrical power consumption, at full load
W
96
117
64
82
Electrical power consumption, at partial load
W
22
22
20
22
Table 14 Technical specifications
1
If the heating capacity is limited to max. 80% (L80).
(50 – 30 °C)