Installation
Water cooling
>
46
300−I−9052003−EN−04/07.2021
5.3
Water cooling
For operating the Mobile devices, a working water cooling system is required.
Operation without water cooling is not permissible and destroys the devices.
A subsequent loosening or tightening of the screws in the cooling cover is not permissible.
The water cooler is mounted in the factory and checked for tightness.
The water cooling has to be dimensioned according the technical data (
¶
How to connect a proper cooling system:
ƒ
Remove the protective caps from the adaptors (delivery status).
ƒ
Connect suction and pressure hoses.
ƒ
Fix and secure the hoses with suitable clips.
ƒ
Fill and vent water cooling.
)
Note!
The cooling circuit can also be vented by vacuuming the entire cooling system,
if the entire cooling system is designed for this.
The MOBILE devices do not have any restrictions here.
Prior to every switch−on, the proper functioning of the cooling needs to be ensured.
EMDAG2..., EMDAG3..., EMDAG4...
20 mm
(DN 20)
8 × 1.2 mm
1.
2.
Æ
25 - 40 mm
£
2 bar
EMDAG004
EMDAG5...
20 mm
(DN 20)
8 × 1.2 mm
1.
2.
Æ
25 - 40 mm
£
2 bar
EMDAG027