Technical data
General data and operating conditions
>
24
300−I−9052003−EN−04/07.2021
Ambient conditions
Climate
Storage
IEC/EN 60721−3−1
1 year 1K22 (−25 ... +55 °C)
3 years: 1K21 (+5 ... +40 °C)
Transport
IEC/EN 60721−3−2
1K23 (−45 ... +70 °C)
Operation
Inverter, DC/DC
converter
−40 ... +85 °C
Coolant
+30 ... +65 °C
Coolant pump switches on at a
coolant temperature of +30 °C
Service life
50000h
at a coolant temperature of
55°C
Humidity, relative
5 ... 100 %
Altitude
MOBILE DCU
MOBILE PSU
MOBILE DCUPSU
EN 61800−5−1
EN 60664−1
0 ... 2000 m amsl
Overvoltage categoryII
2000 ... 4000m amsl
Overvoltage categoryI
MOBILE DCU S
EN 61800−5−1
EN 60664−1
0 ... 3000 m amsl
Overvoltage categoryII
3000 ... 4000 m amsl
Overvoltage categoryI
Pollution
EN 61800−5−1
EN 60664−1
Degree of pollution 4
all plugs closed
Degree of pollution 2
Plugs opened
Vibration resistance
(9.81 m/s
2
= 1 g)
Transport
Operation
ISO 16750−3, code L
vertical, tested with 57.9 m/s
2
horizontal, tested with 57.9 m/s
2
mechanical shock, tested with 500 m/s
2
for 6 ms
Mounting conditions
Mounting place
in commercial vehicles (spring−loaded masses)
Mounting position
MOBILE DCU
MOBILE PSU
MOBILE DCUPSU
^
MOBILE DCU S
^
Mounting clearances
In the connection area
³
150 mm
Observe bend radii for cables and hoses.
More pages
No special requirements
Supply conditions
HV on−board supply
system
Direct connection to the HV on−board supply system
When switching elements are used in the HV on−board
supply system, the DC−bus capacitors must be precharged.
DC−bus operation
l
Permissible
l
Observe maximum contact load.
l
Only use devices with the same voltage range.
Power systems
IT
Standard
TT, TN
On request
Motors
Only use motors that are suitable for operation on the
inverter.