Installation
Connections of MOBILE DCU, PSU, DCU PSU
Addressing CAN bus nodes
>
64
300−I−9052003−EN−04/07.2021
Setting the address offset
Each MOBILE device has one address for the Public CAN and three addresses for the
Private CAN. An address consists of the basic address and the address offset (address =
basic a address offset).
ƒ
Default setting of the address offset: 13 (ID pins are not wired)
ƒ
Default setting of the basic address for Public−CAN: 234
ƒ
Default setting of the basic addresses Private−CAN:
– AppC: 32
– MC (channel 1): 1
– MC (channel 2): 64
The address offset is defined by wiring ID−Pin1...ID−Pin4 to X31. Thanks to the
combinations, 14 different address offsets are possible which means that up to 14 MOBILE
devices can be operated at a CAN bus.
Boot-
Loader
Startup
1
0
12
11
1
3
I
D-Pin1
I
D-Pin2
I
D-Pin3
I
D-Pin4
O
ffs
et
5
7
6
8
I
D-Pin1
I
D-Pin2
I
D-Pin3
I
D-Pin4
O
ffs
et
0
2
1
3
I
D-Pin1
I
D-Pin2
I
D-Pin3
I
D-Pin4
O
ffs
et
4
9
EMDAG033
Fig. 5−1
Wiring at X31
ID−PIN1
X31/12
ID−PIN2
X31/18
ID−PIN3
X31/13
ID−PIN4
X31/19
Offset 13
Default setting
Boot Loader Startup
Device remains in the Boot Loader, firmware is not started.
The length of the wire jumpers may be maximally 50 mm. If the ID pins are double assigned, the
contact must be double crimped.