TS5/TS7 Sensor Features
SMART MATRIX
- 3-11 -
Other factors that may affect the control
DELAY [s]
Is the sensor waiting time before starting the control process, namely the time needed to the machine to
reach the set speed
(Programmable).
TENS [ABS/REL]
It defines the sensor operating mode as regards the calculation of min/max threshold and peak values with
reference to the yarn tension
.
ABS:
ABSOLUTE
mode – all calculations are carried out according to a
constant
reference value
(TENS)
defined by the operator during the article programming phase
(NEW or MODIFY)
which applies to all sensors to which that article has been loaded
(LOAD)
.
The
TENS H
,
TENS L
,
PEAK H
,
PEAK L
and
NOYARN
values too will then be
constant
values with
respect to the
TENS
reference and will always remain unchanged throughout the entire yarn
processing cycle
REL:
RELATIVE
mode – All calculations are carried out according to a reference value
self-learned
by each sensor during the
LEARN
phase, that will remain constant throughout the entire yarn
processing cycle. Even in this case the
TENS H
,
TENS L
,
PEAK H
,
PEAK L
and
NOYARN
values will
be
constant
values, but referred to a specific value
(
relative
)
to each sensor.
KEY [LOCK/UNLOCK]
It defines the Touch Light button operating mode:
LOCK:
The button is enabled for the Automatic Numbering procedure only.
UNLOCK:
The button is enabled not only for the Automatic Numbering procedure, but also for reset in
case of alarm.
MODE [MONITOR-CONTROL]
It defines the operating mode of the system when a defect is detected
MONITOR:
No Failure
=
Green LED lit
TENS H failure
=
1 flash, red LED
PEAK H failure
=
2 flashes, red LED
TENS L failure
=
1 flash, red + green LEDs
PEAK L failure
=
2 flashes, red + green LEDs
NOYARN failure
=
continuous flashing, red LED + STOP output activation
In Monitor mode, as soon as the failure condition disappears, the sensor automatically
resumes the normal operation and turns on the green LED.
CONTROL:
No Failure
=
Green LED lit
TENS H failure
=
1 flash, red LED + STOP output activation
PEAK H failure
=
2 flashes, red LED + STOP output activation
TENS L failure
=
1 flash, red + green LEDs + STOP output activation
PEAK L failure
=
2 flashes, red + green LEDs + STOP output activation
NOYARN failure
=
continuous flashing, red LED + STOP output activation
In Control mode, the failure condition must be reset either through the touch light or through
the ENABLE input (see Note on next page).
Summary of Contents for SMART WARP
Page 1: ...SMART MATRIX WARP Operating Manual ENGLISH Rev 3 0 December 2011 ...
Page 3: ...Introduction i ...
Page 4: ......
Page 9: ...Connections and Electrical Interface 1 ...
Page 10: ......
Page 21: ...Operating Instructions 2 ...
Page 22: ......
Page 79: ...System Components and Configuration 3 ...
Page 80: ......
Page 102: ...SLOW FAST Control Parameters SMART MATRIX 3 22 Page left intentionally blank ...