Style Programming (TS5/TS7)
SMART MATRIX QUILT
2 - 27
Select the row
PRX:P=1…
Set the desired values:
TIMEOUT
,
Delay FAST
[PRXs]
,
Delay SLOW [PRXs]
,
PRESCALER
.(For the
detailed meaning of these parameters, please refer
to section 3)
To confirm che desired option and return to previous
menu.
Select
GROUP#1
Set the identification number of the last device
belonging to the first group (L1D2) and confirm.
To start setting the parameters related to group 1
(
GROUP #1
).
Set desired values in the
FAST
window:
-
Working Tens
: = work tension [set point] [0.1
÷
4.000 gr]
-
LOW
(
%
):minimum tension value, below which
an alarm will be generated
[-1
÷
-100% of the setpoint value]
-
LOW
(
ms
): running time with tension
≤
LOW
after which an alarm will be generated [10
÷
5.000 ms].
-
Tol (Tolerance)
: [1
÷
250] (*)
-
HIGH
(
%
): maximum tension value, above
which an alarm will be generated
[1
÷
999% of the setpoint value]
-
HIGH
(
ms
): running time with tension
≥
HIGH
after which an alarm will be generated [10
÷
5.000 ms].
-
Tol (Tolerance)
: [1
÷
250] (*)
To move to the setting of parameters related to next
group (
GROUP#2
) or to save the style to the
database once you have setup all the parameters.
(*) The alarm will be generated only if the contitions specified with
LOW / HIGH (%)
and
LOW / HIGH
(ms)
parameters
persist for the number of PRX pulses specified with this parameter.
=alarm enabled
=alarm disabled
Summary of Contents for SMART MATRIX QUILT
Page 1: ...SMART MATRIX QUILT Operating Manual ENGLISH Rev 1 1 January 2010 ...
Page 3: ...Introduction i ...
Page 4: ......
Page 8: ...Table of Contents SMART MATRIX QUILT iv Page left intentionally blank ...
Page 9: ...Connections and Electrical Interface 1 ...
Page 10: ......
Page 19: ...Operating Instructions 2 ...
Page 20: ......
Page 61: ...System Information 3 ...
Page 62: ......