Differences between TS5 and TS7 Sensors
SMART MATRIX QUILT
3 - 7
Differences between TS5 and TS7 Sensors
The TS5 and TS7 sensors are basically identical in terms of functionality, performance, control parameters,
etc. The only difference being the electrical interface:
TS5
=
Built-in cable with either 4 or 8 pin
(*)
connector
TS7
=
2 built-in connectors for “daisy-chain” connection (like IS3F)
(*)
The 8 pin connector is not used on SMART MATRIX WARP application.
TS5 8 pin
TS5 4 pin
TS7
1 +VCC
2 GND
3 RX
TX+
4 RX
TX-
5 STOP
6 GND
7 ANAL.
8 ENABLE
1 +VCC
2 GND
3 RX
TX+
4 RX
TX-
[Recommended !]
Technical Characteristics
TS5
TS7
Power supply voltage
12-24 VDC ± 10%
24 VDC ± 10%
Current absorption
45 mA Max
30 mA Max
Analogic output (only for TS5 – 8 pin)
100 mV – 5 V
----
Analogic output resistance (only for TS5 – 8 pin)
1K Ohm
----
Operating temperature range
+10° / +50°
+10° / +50°
Storage temperature range
-25° / +85°
-25° / +85°
Tension range
0 – Full Scale
0 – Full Scale
Useful tension range
0% - 95% FS
0% - 95% FS
Max applicable tension
10 times FS
10 times FS
Drift error
0.05%/°C
0.05%/°C
Repeatability error
0.5%
0.5%
Max linearity error
1% (0 – FS)
1% (0 – FS)
Communication bus
RS485
RS485
Overall dimensions
50x25x12.5 mm
50x25x12.5 mm
Summary of Contents for SMART MATRIX QUILT
Page 1: ...SMART MATRIX QUILT Operating Manual ENGLISH Rev 1 1 January 2010 ...
Page 3: ...Introduction i ...
Page 4: ......
Page 8: ...Table of Contents SMART MATRIX QUILT iv Page left intentionally blank ...
Page 9: ...Connections and Electrical Interface 1 ...
Page 10: ......
Page 19: ...Operating Instructions 2 ...
Page 20: ......
Page 61: ...System Information 3 ...
Page 62: ......