Installation and Connections
MATRIX CUBE
- 11 -
DIAPERFEEDER IP54 Device Technical Characteristics
Power supply voltage
24 VDC ± 10%
0.2 A
(during normal operation);
1 A
(under stress);
Maximum absorption
3 A
(at start-up)
STOP Outputs: relay contacts (NO)
0.3 A 125 VAC
1 A 30 VDC
Opto-insulated Inputs
0-24 VDC
V
IL
Max 1,2 VDC
V
IH
Min 5 VDC
Programmable yarn tension (100g version 0.5
÷ 100 gr. (resolution 0.1 gr.)
Programmable yarn tension (1000g
version
5
÷ 1000 gr. (resolution 1 gr.)
Programmable alarms
0.1 ÷ 25 sec.
Dimensions
220 x 86 x 98 mm
Operating temperature range
10° - 60 °C
Storage temperature
-25° - +85° C
Tension range
0 / full scale
IP degree
IP54
TS44.. Sensor (DIAPER FEEDER) Technical Characteristics
Power supply voltage
12 .. 24 Vdc ± 10%
Absorption 20
mA
(max)
Analogue Output
100 mV - 10V
Analogue output resistance
1K Ohm
Operating temperature range
10° - 50 °C
Storage temperature
-25° - +85° C
Tension range
0 - full scale
Useful tension range
0% - 95% full scale
Max applicable tension
10 times the full scale value
Drift error
0.05% / °C
Repeatability error
0.5%
Max linearity error
2% (0 - full scale)
Signaling
With integrated LEDs
Dimensions
50 x 25 x 12.5 mm
Summary of Contents for MATRIX CUBE
Page 1: ...MATRIX CUBE Operating Manual ENGLISH Rev 4 2 April 2014 ...
Page 3: ...Introduction i ...
Page 4: ......
Page 10: ...Introduction MATRIX CUBE vi Page intentionally left blank ...
Page 13: ...Installation and Connections 1 ...
Page 14: ......
Page 40: ...Installation and Connections MATRIX CUBE 26 Page intentionally left blank ...
Page 41: ...Operating Instructions 2 ...
Page 42: ......
Page 87: ...Error Messages 3 ...
Page 88: ......
Page 91: ...DIAPER FEEDER Device 4 ...
Page 92: ......
Page 117: ...Maintenance of MATRIX CUBE System 5 ...
Page 118: ......
Page 123: ...Sign Off A ...
Page 124: ......
Page 128: ...Sign Off Procedure at System Reception MATRIX CUBE 104 Page intentionally left blank ...