3.4.3 Change the punch.
1.
Remove battery from the power unit
2.
Remove the C-frame see section 3.4.1.
3.
Loosen the allen screw which hold the punch (pic 5).
4.
Remove stripper from the punch (pic 6)
5.
Make sure it is the right article no at the new punch
6.
Mount the new punch, tighten the mounting screw
7.
Montera den nya stansen, dra åt låsskruven (bild 5).
8.
Återmontera C-bygeln, se avsnitt 3.4.4.
Kontrollera CT (knappens tjocklek) och/eller BD (knappens diameter) mått efter varje byte av
stans eller dyna.