9
Before connecting the FPC-900i interface to an AC power source,
check that the voltage selector switch on the side panel is correctly set.
If a change is necessary then ensure that the mains fuse is changed for
one of the correct current rating
Refer to Section 2.6 'Installation' - AC Power and Fusing.
2.3 Mains Power
As the colours of the wires in the mains lead may not correspond with
the markings identifying the terminals in your plug, proceed as follows.
!
The wire which is coloured Green and Yellow or Green must be
connected to the terminal which is marked with the letter ‘E’ or by
the Earth signal
or which is coloured Green and Yellow or
Green.
"
The wire which is coloured Blue must be connected to the terminal
labelled ‘N’ or coloured Black or Blue.
#
The wire which is coloured Brown must be connected to the
terminal labelled ‘L’ or coloured Red or Brown.
Those units supplied to the North American market will have an
integral moulded 3 pin connector which is provided to satisfy required
local standards.
Fig 2.2 Overall
dimensions of the
FPC-900r Remote
WARNING! THIS APPLIANCE MUST BE EARTHED.
IMPORTANT: The wires in the mains lead are colour coded in
accordance with the following code.
Green and Yellow......Earth
Blue......Neutral
Brown......Live