25
3.4 Interface
Controls and
Connections
Interface Controls and Connections
The FPC-900i pink noise output can be turned on and off from the
remote. Press UTILS and select MORE
or
press RTA. The menu item
named PINK will turn the noise output on and off. The pink noise
output level is approxi1dBu.
See Section 9.3 'MORE Sub-
menu'.
This 5 pin connector carries the power and data link to the Remote
using the supplied multicore cable. This connector is wired in parallel
with the connector labelled REMOTE INTERFACE on the rear panel
(See 'M').
Refer to Section 2.7 'Data Connections and Midi'.
This led indicates a charging fault with the Remote internal battery.
The interface cannot charge the battery due to disconnection or a
battery fault. There is also a protection fuse on the battery circuit
within the Remote.
Refer to Section 2.9 'Internal Battery'.
This 3 pin socket is a Frequency Shift Keying (FSK) data input from the
remote. This connector carries control data from the remote to the
interface through a standard audio cable or wireless link. Note that this
data is one way only. No data is returned from the controlled
Varicurve units to the remote. This connector is wired in parallel with
the connector labelled FSK INPUT on the rear panel (See 'L').
Refer to
Section 2.8 'FSK'.
This led indicates an error in the data received on the FSK input.
Possible causes are loss of transmission if a radio link is in use, or
insufficient signal level, noise or interference.
N
PINK NOISE OUTPUT
A
REMOTE INTERFACE
B
FAULT LED
C
FSK INPUT
D
ERROR LED
E
Summary of Contents for FPC900r