51
A13122
6.4.1.
Electric Heat
If you have a fan coil with electric heaters, this menu item will allow the heaters to
be exercised. With self--identifying electric heaters, three stages of electric heat are
available to be exercised in any combination. Non--identifying heaters will only
provide one stage of heat. After the selections are made, touch
START
.
S
Low Heat:
Selectable from 0 to 120 minutes
d
Default = 5 minutes
S
Medium Heat:
Selectable from 0 to 120 minutes
d
Default = 5 minutes
S
High Heat:
Selectable from 0 to 120 minutes
d
Default = 5 minutes
6.4.2.
Furnace
Make sure the furnace is properly installed.
This option allows the furnace to be exercised. First, a low heat run time and high
heat run time are selected. The furnace will execute its ignition start--up sequence.
This sequence will be displayed on the screen. After the gas valve and blower