L4006A High Limit Aquastat Control..............................................................................................................................................................20
Draft Inducer Temperature Safety Switch........................................................................................................................................................23
Casting Temperature Safety Switch..................................................................................................................................................................23
Differential Pressure Air Proving Switch .........................................................................................................................................................23
Draft Inducer......................................................................................................................................................................................................23
Circulator Pump.................................................................................................................................................................................................23
Drain Valve........................................................................................................................................................................................................23
ASME Rated Pressure Relief Valve .................................................................................................................................................................23
Flame Rollout Safety Shutoff ...........................................................................................................................................................................23
(Optional) External Condensate Pump .............................................................................................................................................................23
START-UP PROCEDURES........................................................................................................................................................................................24
Water Treatment and Freeze Protection ................................................................................................................................................................24
Filling Boiler with Water and Purging Air for Systems with Diaphragm Type Extension Tanks .....................................................................24
Filling Boiler with Water and Purging Air with Conventional Closed Type Expansion Tanks .........................................................................24
Placing Boiler In Operation....................................................................................................................................................................................24
Check Out Procedure and Adjustments .................................................................................................................................................................25
Verify Proper Sequence of Operation ..............................................................................................................................................................25
Inspect Venting and Air Intake System............................................................................................................................................................25
Inspect Condensate Drain..................................................................................................................................................................................25
Inspect System Piping .......................................................................................................................................................................................25
Test Ignition System Safety Shutoff Device ....................................................................................................................................................25
Test High Limit Control and Adjust ................................................................................................................................................................26
Test Other Safety Controls................................................................................................................................................................................26
Set Thermostat Heat Anticipator (If Used) and Verify Thermostat Operation ..............................................................................................26
Measure the Gas Input Rate..............................................................................................................................................................................26
Set Thermostat to Desired Room Temperature................................................................................................................................................28
Review All Instructions.....................................................................................................................................................................................28
Complete and Sign the Installation and Check-Out Certificate ......................................................................................................................28
CARE AND MAINTENANCE...................................................................................................................................................................................28
Beginning of Each Heating Season........................................................................................................................................................................28
Daily During Heating Season.................................................................................................................................................................................29
Monthly During Heating Season............................................................................................................................................................................29
Periodically During Heating Season ......................................................................................................................................................................30
End of Each Heating Season — Annual Shut Down Procedure ..........................................................................................................................30
Annual Examination and Cleaning of Boiler Components ...................................................................................................................................30
Differential Air Pressure Switch Check.................................................................................................................................................................31
Service Hints...........................................................................................................................................................................................................31
Repair Parts.............................................................................................................................................................................................................44
SAFETY CONSIDERATIONS
Recognize safety information. This is the safety-alert symbol
. When you see this symbol on the furnace and in instructions or manuals, be alert
to the potential for personal injury. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. These words are used with the
safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a
hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury
or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
These instructions cover minimum requirements and conform to existing national standards and safety codes. In some instances, these instructions
exceed certain local codes and ordinances, especially those that may not have kept up with changing residential construction practices. We require
these instructions as a minimum for a safe installation.
Fig. 1—BW9 Boiler
A99365
—2—
Summary of Contents for BW9
Page 37: ...Fig 29 Troubleshooting Chart No 1 A00318 37 ...
Page 39: ...Fig 31 Troubleshooting Chart No 3 A00319 39 ...
Page 40: ...Fig 32 Troubleshooting Chart No 4 A00320 40 ...
Page 41: ...Fig 33 Troubleshooting Chart No 5 A00321 41 ...
Page 42: ...Fig 34 Troubleshooting Chart No 6 A00322 42 ...
Page 46: ...Fig 38 Boiler Block and Piping Assembly A99176 46 ...
Page 51: ... 51 ...
Page 52: ... 2003 CAC BDP 7310 W Morris St Indianapolis IN 46231 imbw9a03 52 Catalog No 63BW 9A4 ...