Technical data
and startup
36
7
Level of inverter efficiency
7.1
DMC514 measured with HSM1-10.18.04 at 400V (first quadrant)
DMC514
Torque [Nm]
Sp
ee
d
[
rp
m]
0
10
20
30
40
50
60
70
80
90
100
110 120 130 140 150
1000
77.39 79.95 84.24 86.43 87.75 88.65 89.30 89.78 90.13 90.35
2000
80.93 87.80 90.47 91.90 92.79 93.38 93.88 94.15 94.11 94.21
3000
90.18 93.43 94.56 95.12 95.40 95.53 95.57 95.54 95.48 95.38
4000
90.27 93.15 94.75 95.50 95.96 96.22 96.40 96.52 96.57 96.56
5000
90.44 94.36 95.69 96.27 96.62 96.90 97.05 97.07 96.85
6000
92.00 95.11 96.86 97.36 97.56 97.66 97.33 97.30 97.25
7000
93.06 95.84 96.99 97.43 97.63 97.21 97.10
8000
93.75 96.10 96.87 97.28 97.20 97.10
9000
94.24 96.30 96.95 97.16 97.15
10000
94.60 96.45 97.01 97.15
11000
94.87 96.61 97.13 97.05
12000
96.44 97.26 97.30
*The efficiency map is only valid for the inverter
7.2
DMC524 measured with HSM1-6.17.12 at 400V (first quadrant)
DMC524
Torque [Nm]
Sp
e
e
d
[r
p
m]
10
20
30
40
50
60
70
80
100
120
140
160
180
200
220
1000
74.32 82.62 86.02 87.79 88.80 89.47 89.93 90.25 90.65 90.81 90.83 90.80 90.62 90.40 90.14
2000
84.56 89.84 91.91 92.94 93.54 93.95 94.22 94.41 94.65 94.74 94.72 94.65 94.52 94.36 94.18
3000
88.77 92.68 94.19 94.95 95.39 95.70 95.88 96.01 96.18 96.23 96.20 96.13 96.04 95.89 95.73
4000
91.05 94.28 95.52 96.13 96.47 96.69 96.84 96.92 97.04 97.06 97.04 96.95 96.84 96.71 96.57
5000
92.64 95.36 96.38 96.90 97.17 97.36 97.48 97.54 97.55 97.49 97.35 97.12 96.88 96.90 96.98
6000
93.85 96.18 97.06 97.42 97.60 97.68 97.71 97.70 97.60 97.41 97.04 96.91 96.93 96.94
7000
94.77 96.74 97.33 97.61 97.72 97.75 97.74 97.71 97.50 97.01 96.94 96.95
8000
95.51 97.01 97.49 97.68 97.76 97.78 97.76 97.64 97.21 97.11 97.13
9000
95.84 97.18 97.61 97.78 97.82 97.82 97.72 97.54 97.23 97.26 97.11
10000
95.87 97.11 97.67 97.82 97.88 97.79 97.60 97.26 97.23 97.22
11000
95.91 97.26 97.69 97.81 97.83 97.69 97.48 97.26
12000
95.96 97.35 97.74 97.87 97.82
*The efficiency map is only valid for the inverter