Technical data
and startup
54
9.1
System requirements for
PARAM-tool
software
Windows XP / Vista / WIN7 (32Bit /64Bit)
Serial port RS232 (firmware download)
9.2
Ventilate and check cooling system
INSTRUCTION
Air pockets in the cooling passage along with generally insufficient cooling of the inverter lead to
increased wear!
Ensure that the cooling circuit is fault-free.
PROCEDURE STEP
ILLUSTRATION / OTHER INFORMATION
1.
Switch on the cooling circuit.
–––
2.
Leave the cooling circuit on for around 30 s.
To avoid the overheating of the device, flow must be
ensured as soon as the inverter is switched on via
CAN enable
!
3.
Switch off the cooling circuit.
–––
4.
Check the cooling water level.
–––
9.3
Load motor parameter table onto inverter
To ensure the smooth driving of the motor, motor parameter tables corresponding to BRUSA motors are also
provided. These must be installed on the inverter using the
PARAM-Tool
software.
If using other brands of motor, the corresponding tables must be invoiced for and developed by BRUSA Elektronik
AG!
You will find instructions for installation and settings in the manual
PARAM_Manual.pdf