9.21 Multi-feed sensor PCB (Transmit) /
Multi-feed sensor PCB flat cable (Transmit)
(1) Unlock the lock to disconnect the multi-feed sensor PCB flat cable (Transmit) from the
multi-feed sensor PCB (Transmit).
(2) Remove the taptite cup B M3x8 screw to remove the multi-feed sensor PCB (Transmit)
from the upper base ASSY while lifting the FG plate.
Fig. 3-53
Harness routing: Refer to
.
Note:
• After disconnecting flat cable, check that the cable is not damaged at its end or
short-circuited.
• When connecting flat cable, do not insert it at an angle. After insertion, check that
the cable is not at an angle.
Taptite cup B M3x8
Multi-feed sensor PCB (Transmit)
Multi-feed sensor PCB flat cable (Transmit)
Upper base ASSY
FG plate