9.18 ADF cover sensor PCB / Sensor PCB flat cable
(1) Unlock the lock to disconnect the sensor PCB flat cable from the ADF cover sensor
PCB. Disconnect the second side LED light PCB harness, the paper detection sensor
harness and the multi-feed sensor PCB flat cable (Transmit) from the ADF cover sensor
PCB.
(2) Remove the taptite cup B M3x8 screw to remove the sensor PCB FG harness and the
anti static brush FG harness. Remove the ADF cover sensor PCB from the upper base
ASSY while lifting the FG plate.
(3) Remove the flat core and the sensor PCB flat cable from the upper base ASSY, and
release the sensor PCB flat cable from the securing fixtures.
Fig. 3-42
Harness routing: Refer to
and
.
Note:
• After disconnecting flat cables, check that each cable is not damaged at its end or
short-circuited.
• When connecting flat cables, do not insert them at an angle. After insertion, check
that the cables are not at an angle.
Note:
• Be careful not to bend the FG plate.
Note:
• Be sure to replace the double-sided tape with a new one, after taking off the flat
cable and the flat core from the double-sided tapes.
Multi-feed
sensor PCB
flat cable
(Transmit)
FG plate
Second side LED light PCB harness
ADF cover sensor PCB
Sensor PCB flat cable
Taptite cup B M3x8
Anti static
brush FG
harness
Upper
base ASSY
Sensor
PCB FG
harness
Paper detection sensor harness
Flat core
Summary of Contents for PDS-5000
Page 23: ...2 4 Confidential 2 2 Document Feed Path Fig 2 2 Front side Document feed path Back side ...
Page 45: ...3 2 Confidential 2 PACKING Fig 3 1 ...
Page 48: ...3 5 Confidential 5 LUBRICATION There are no parts that require lubrication ...
Page 49: ...3 6 Confidential 6 OVERVIEW OF GEARS Left side Fig 3 3 Right side Fig 3 4 ...
Page 138: ...5 1 Confidential CHAPTER 5 SERVICE FUNCTIONS Service mode is not equipped with this product ...